1- Air fl ushing
Meter must be completely fl ushed to work correctly (cf.
LCD after correct fl ushing (cf.
LCD after incorrect fl ushing. Air in pipe icon blinking displayed. (cf.
2- Pulse output connection (cf.
Brown = Pulse
Gray = Ground
Yellow = Cable cut Tamper or DIR
Note: Itron recommends 0.4-0.9 mm, pre-bonded or solid conductor wire with a maximum diameter of 2.1 mm
(individual wire insulation). The use of un-bonded wire may produce an unreliable connection when using gel caps, type
UY2 (BX), for joining wires. Total Lenght of additional cable must be maximum 1.5 m.
3- Environmental Protection
Environmental Temperature
Restriction for High Temperature on
Yearly Basis
Storage Temperature
Transport
Electromagnetic Class
4- LCD overview
4.1 General LCD overview (cf.
The lid must be closed to better protect LCD display against direct sunlight.
4.2 Display overview
Icons
1
2
3
4
5
6
7
m
3
8
m
/h
3
9
4.3 LCD activation/control
The LCD display is controlled through the front lid. When the lid is open, the display is switched on.
Opening the lid automatically starts the display sequence.
If the lid remains open, the LCD display switches off after a complete sequence.
)
2
)
4
-25°C to 70°C
3 months with max 55°C for 18 hours/day & max 70°C for 6 hours/day
9 months with max 30°C for 18 hours/day & max 50°C for 6 hours/day
5°C to 35°C
Min -25°C (< 72 hours continuous)
Max +70°C (< 72 hours continuous)
E2
E1 (for pulse output)
)
5
Information
Main display 8/9 digits
Air in pipe indicator
System or application
Alarm indicator
Leakage indicator
Test mode indicator
Recalibration indicator
Battery level indicator
Volume unit indicator
Flowrate unit indicator
)
1
)
3
Blinking
--
Air in pipe for more than 1 minute
System or Application alarm
Leakage
Product re-calibration done
12 Months remaining battery
(After battery end of life expected date,
FDR are not saved in memory)
Flowrate detected
--
--
Permanent
Rolling display :
Index, Flowrate, ...
--
System Alarm Display
--
Product in Test Mode
--
--
Current Flowrate
Application Alarm Display