Manual RRC-SMB-DBC
RRC SMBUS D
B
UAL
ATTERY
C
HARGER
Manual RRC-SMB-DBC
RRC SMBUS D
B
UAL
ATTERY
.en
This battery charger may not be located in the vicinity of a patient.
In accordance with EN60601-1-1, the horizontal distance must be at least
1.5 meters.
Do not insert a fully charged battery into the charger repeatedly. Due to the
high initial charge, the battery could be overcharged which could lead to
damage to the battery and to the battery charger
Use the battery charger only in dry indoor environments! Wet and moisture
covered products should not be used!
This product has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
FCC Advice,
frequency energy and, if not installed and used in accordance with the
valid in USA
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
•
•
•
•
Changes or modifications of the device are not allowed.
Declaration of Conformity:
The battery charger complies to the current regulations of the EU guidelines.
Symbols
Caution / Warning
Instructions for use
Use only in enclosed spaces
Sign of conformity to the applicable EC Directives
The product should be disposed of according to local guidelines
RoHs (China)
DC voltage
Mark of compliance to the California Energy Commision requirements
Technical Specifications
Battery Charger
Input Voltage
19 - 26VDC / 3.4A max.
Charging and Output Voltages
0 - 17.4VDC / 0 - 4.8A
Power
2 x 30W
Measurements
178 x 160 x 45.5 mm
(L x B x H)
Operating / Storage Temperature
0°C to 40°C / -10°C to 70°C
Weight
310g
Safety Standards /
IEC/EN60950-1 UL60950-1* / EN55011 / EN55022 / EN55024* / FCC15 class B /
EMC Standards
IEC/EN61000-4-2,-3,-4,-5,-6,-8,-11* / EN61000-3-2,-3-3*
* valid only for power supply
C
HARGER
E
NGLISH
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Power Supply
100-240VAC / 50 - 60Hz
19VDC ± 5% / 3.4A
65W
95 x 51 x 25.4 mm
0°C to 40°C / -10°C to 70°C
270g
3