8
CONNECTION/WIRING DIAGRAM
TAB
Model
Amperage
Amps
Sense U 7 Pure/Elite
Sense U 8 Pure/Elite
Note: Heating elments do not change for voltage changes. The heater output will changed based on the voltage applied to heater.
ELITE
1A
2A
6A
15
14
13
10
3 x 14 AWG
RJ10 4P4C
RJ10 4P4C
max 75 feet
*
Figure 18: Wiring diagram
1A. NTC Sensor
2A. Ext switch (External switch option-
al)
3A. N/A
4A. N/A
5A. N/A
6A. N/A
7A. N/A
8A. N/A
9A. Controls Elite
208 V 1 Phase
Output
Wire Size
kW
AWG
26
5,3
10
30
6,3
8
3A
4A
5A
7A
8A
9A
1 2
3 4
6
7
8
12
*
RJ10 4P4C
1B. NTC Sensor
2B. Ext switch (External switch optional)
3B. N/A
4B. N/A
5B. N/A
6B. N/A
7B. N/A
8B. Controls Pure
240 V 1 Phase
Amperage
Output
Amps
kW
30
7,0
35
8,3
PURE
1B
5
9
11
5,3-8,3 kW
208/240 V~
Wire Size
AWG
8
8
2B
3B
4B
5B
7B
G
10. Heater
11. Terminal for connection of electrical cable
12. Control panel
(Elite - connect to positions 9A)
(Pure - connect to positions 8B)
13. Light/terminal for connection of light
14. Door contact (option)
15. External switch (option)
6B
8B
13