4 ELECTRICAL CONNECTIONS
Signal
Outputs relay 1 and 2
Fan
Digital intakes 1 and 2
NTC temperature probe
Description
Outputs that acts depending on how they have been programmed.
These outputs are potential free and have a maximum load of 5 ampe-
res at 230 Vac.
If there are lights (par. 4.1) relay 1 remains directly occupied for this
purpose.
If there is a chlorinator (par. 3.1) relay 2 remains directly occupied for
this purpose.
When wall-mounted, as there is no cooling from the motor's own
fan, the ventilation system of the wall mounting shall be used for this
cooling.
This output is 24 Vdc and it is activated whenever the frequency con-
verter is giving a voltage output; its maximum load is 9 W.
Any potential free contact that will perform the programmed functions
can be connected to these intakes.
If there is a heater (par 6.1) digital intake 2 is directly reserved for this
purpose.
N.B. Do not apply voltage to these intakes.
If there is an NTC temperature probe (par. 9.1) it must be connected
here to monitor the water temperature and start up the pump to pre-
vent freezing.
[e] Winner
23