Low Voltage Cut-off
This function helps to prevent battery over-discharge. The
ESC continuously monitors the battery's voltage. If the
voltage becomes lower than the threshold for 2 seconds,
the output power is shut off and the red LED flashes twice
repeatedly.
Start mode "punch"
This parameter sets the initial throttle punch when the car
accelerates. Level1 gives a softer initial acceleration and level
9 gives a stronger initial acceleration.
Max brake force
This parameter adjusts the maximum breaking force. A
higher value provides stronger braking but also makes the
ESC to run hotter and may cause overheating issues.
Motor rotation direction
This parameter adjusts the motor rotation direction, counter
clockwise (CCW, default) or clockwise (CW).
Restore Default Settings
With the throttle in the neutral position, press and hold the
SET button for 5 seconds, the red and green LED will flash
simultaneously indicating that the parameters have been
reset to the factory default values.
www.teamorion.com