EN – Instruction manual
Permissible use
The radiator may only be used for heating in-
terior spaces and for drying textiles washed in
water.
Any other use is contrary to its intended pur-
pose and therefore not permissible.
Misuse
The radiator is not suitable for seating or as a
climbing or scaling aid.
Safety instructions
WARNING
Risk of burning!
The radiator's surface can reach heat of up
to 110 °C (230 °F).
Be careful when touching the radiator.
►
CAUTION
Risk of scalding due to squirting hot water
when evacuating air!
►
Protect your hands.
Additional electric operation
Observe separate instructions for the heat-
►
ing element.
►
Ensure that the radiator is always com-
pletely filled with water and is deaerated,
so that the radiator heats up properly.
Do not operate the hot water heater and
►
the heating element simultaneously.
Ensure that the return is open.
►
Close the thermostatic head.
►
Maintenance
Vent the radiator after commissioning and
►
following lengthy interruptions of opera-
tion.
Cleaning
►
Use only mild, non-scouring cleaning
agents.
Complaint
Please contact your specialist.
►
Installation and repairs
Only let a specialist carry out installation
►
and repair work to prevent any guarantee
claims from being rendered null and void.
Disposal
►
Recycle or dispose of disused radiators, in-
cluding accessories, properly. Observe local
regulations.
EN – Installation instructions
The radiator may only be installed by a special-
ist.
For additional electric operation, the following
activities may only be performed by an electri-
cal specialist:
•
Installation and connection of the electric
set
•
Connection of the heating element to the
electric set
An electrical specialist is someone whose tech-
nical training, knowledge, experience and
knowledge of the relevant regulations allows
him to assess the tasks assigned to him and rec-
ognise potential hazards.
Safety instructions
►
Read these instructions for installation and
use thoroughly prior to installation/commis-
sioning.
►
After installation, pass the instructions on
to the end user.
Observe the safety directions in the sepa-
►
rate electric set instructions.
DANGER
Life-threatening situation!
►
Check the condition of the supply lines
(electricity, gas, water).
Do not drill into any lines.
►
WARNING
Risk of injury!
►
Note the radiator's weight (see page 6).
►
At 25 kg and above work with lifting
equipment or several persons.
WARNING
Personal injury and material damage!
Check substrate for load-bearing capaci-
►
ty. Note the radiator's filled weight (see
page 6) and viable added weight.
►
Check fasteners for applicability and tai-
lor them to the structural situation.
Take special requirements, e.g. for public
►
buildings (schools or the like), into ac-
count.
Conditions of use
►
Observe operating conditions for water
heating installations according to local reg-
ulations.
►
Maintain water quality according to local
regulations.
Observe usage limits in humid spaces ac-
►
cording to local regulations.
Use radiator only in closed heating systems.
►
►
Store and transport radiator only in the pro-
tective packaging.
For additional electric operation:
►
Select heating element heat output accord-
ing to the radiator type (see current sales
documents).
When installing in rooms with bath or
►
shower facilities: Take protective ar-
eas as per DIN VDE 0100-701 into ac-
count. Also follow all local regulations.
Note: The manufacturer does not approve
the installation of products in safety area 1.
Recommendation according to IEC stand-
►
ard 60335-2-43: To prevent any risk to small
children, install the radiator so that the bot-
tommost cross tubes are situated at least
600 mm above the floor.
Ensure that when the valve in the flow is
►
closed, the water in the radiator can ex-
pand up to the expansion vessel.
►
When installing a valve in the return, en-
sure that the valve can only be actuated
with a tool, in order to prevent unauthor-
ised blocking.
Complaint
►
Contact the manufacturer.
Disposal
►
Packaging should be recycled or disposed
of properly. Observe local regulations.
Technical features
•
Operating pressure: max. 10 bar
•
Test pressure: 1.3 x operating pressure
•
Flow: available on the right or the left
•
Flow temperature:
–
Hot water up to 110 °C (230 °F)
–
for additional electric operation up to
80 °C (176 °F)
Directions for installation
For installation as room divider:
Observe separate instructions for fasteners.
►
For additional electric operation:
►
Observe the electric set installation instruc-
tions.
Ensure that a correctly mounted mounting
►
box or wall socket (230 V, 16 A fuse) is avail-
able within the reach of the cable.
The wall emanating electrical connection must
be freely accessible and must not project out
to the surface of the radiator or the control
unit.
The radiator must not be attached directly be-
neath a wall socket.
For installation in a one-pipe heater:
►
Use connection fitting with integrated, ad-
justable bypass.
3