Diagram of Outdoor Unit Installation
2-5.
Never install only a single indoor unit.
(1) GRF148MR5I
Be sure to connect indoor and outdoor units only in
combinations that are listed in the catalog or in the
combination table that was provided with the outdoor unit.
(Use caution. Connecting any other model may result in
operation failure and malfunction.)
The dimensions indicated by
spaces that are required in order to maintain
performance. Install in a location where the dimensions
indicated by
of the unit are unobstructed. In principle, the top direction
should be unobstructed.
Ensure 15cm
of space if a
drain hose is to
be used.
Base (not provided)
(concrete or similar material)
in the figure below are
are ensured, and where 2 or more faces
Power breaker
B
A
Fasten with anchor bolts
(not provided)
(3/8" or M10, 4 locations)
Fig. 6e
11
Service space
Access panel C
Ground
wire
(not
provided)
Indoor unit B
Indoor unit A