Replacing the blade (Fig. XIX, XX, XXI, XXII)
WARNING: Unplug the mitre saw before changing/installing the Blade (28).
1) Select a 254mm Blade with a 25.4mm arbour, making sure the rotation arrow on
the Blade matches the clockwise rotation arrow on the upper guard, and the
Blade teeth are pointing downward
2) Place the Blade, the Outer Blade Collar (71) against the Blade and on the arbour.
Thread the Arbour Bolt (69) on the arbour in a counter clockwise direction
IMPORTANT: Make sure the flats of the blade collars are engaged with the flats on
the arbour shaft. Also, the flat side of the blade collar must be placed against the
Blade (28).
3) Place the Blade Spanner (35) on the Arbour Bolt
4) Press the Arbour Lock (70), holding it in firmly while turning the Blade counter
clockwise. When it engages, continue to press the Arbour Lock in, while
tightening the Arbour Bolt securely
5) Rotate the Cover Plate (68) and Lower Blade Guard (3) back to its original
position
6) Replace the the Cover Plate Screw (67) and tighten with a Phillips screwdriver.
7) Verify the operation of the Lower Blade Guard does not bind or stick
8) Be sure the Arbour Lock is released so the Blade turns freely
Replacing the guide fence (Fig. XXIII)
IMPORTANT: The left side Guide Fence (11) must be removed when making any
right bevel angle cuts greater than 33.9° in combination with any right or left mitre
angle. This Guide Fence must also be removed when making left bevel cuts greater
than 40° with a mitre angle greater than 31.6°.
1) Unlock the Guide Fence Locking Lever (24) by pushing it out towards the rear of
the saw.
2) Align the Guide Fence Slot (72) with the Guide Fence Rear Bolt (73) in the rear
of the Guide Fence, and then lift up the Guide Fence to remove it from the saw.
3) To replace the Guide Fence, align the Guide Fence Slot with the Guide Fence
Rear Bolt in the rear of the Guide Fence to place the Guide Fence onto the mitre
saw fence.
4) Slide the Guide Fence to align the Back Nut (74) with the Back Slot (75).
5) To lock the Guide Fence, push the Cam Locking Lever (24) in towards the front
of the saw.
Carbon brushes (Fig. XXIV)
WARNING: Always disconnect the plug from the power source before inspecting
the brushes.
Check the motor brushes after the first 50 hours of use for a new machine or
after a new set of brushes have been installed.
After the first check, examine them every 10 hours of use. When the carbon is
worn to 6 mm in length or if the spring or shunt wire is burned or damaged,
replace both brushes.
If the brushes are found serviceable after removing, reinstall them.
To inspect or replace brushes, first unplug the saw. Next, remove the two Fixing
Screws (76) and the motor Rear Motor Cover (77) from the motor. Carefully
remove the Spring-Loaded Cap (78) on the side of the motor. Third, pull out the
Carbon Brush (79) and replace. The ears on the metal end of the assembly go in
the same hole the carbon part fits into. Last, tighten the cap snugly, but do not
overtighten.
Repeat above procedure for the Carbon Brush located on the other side of the
motor.
Note: To reinstall the same brushes, first make sure the brushes go back in the way
they came out. This will avoid a break-in period that reduces motor performance and
increases wear
Contact
For technical or repair service advice, please contact the helpline on
(+44) 1935 382 222
Web: tritontools.com/en-GB/Support
Address:
Toolstream Ltd.
Boundary Way
Lufton Trading Estate
Yeovil, Somerset
BA22 8HZ, United Kingdom
tritontools.com
Guarantee
To register your guarantee visit our web site at
tritontools.com* and enter your details.
Purchase Record
Date of Purchase:
___ / ___ / ____
Model: TCMS254
Retain your receipt as proof of purchase
Triton Precision Power Tools guarantees to the purchaser of this product that if
any part proves to be defective due to faulty materials or workmanship within
3 YEARS from the date of original purchase,
Triton will repair, or at its discretion replace, the faulty part free of charge.
This guarantee does not apply to commercial use nor does it extend to normal
wear and tear or damage as a result of accident, abuse or misuse.
* Register online within 30 days.
Terms & conditions apply.
This does not affect your statutory rights
Australian Warranty Information
You may wish to register your product at www.tritontools.com but you are not
under any obligation to do so.
Our goods come with guarantees that cannot be excluded under the Australian
Consumer Law. You are entitled to a replacement or refund for a major failure
and for compensation for any other reasonably foreseeable loss or damage.
You are also entitled to have the goods repaired or replaced if the goods fail to
be of acceptable quality and the failure does not amount to a major failure.
This product is guaranteed against faulty materials and workmanship for
3 YEARS from the date of purchase. Please retain your receipt as proof of
purchase.
This warranty does not cover defects caused by or resulting from:
(a) misuse, abuse or neglect;
(b) trade, professional or hire use;
(c) repairs attempted by anyone other than our authorised repair centres; or
(d) damage caused by foreign objects, substances or accident.

Warranty Exclusions

Wearing parts, consumable items or service-related parts required when
performing normal and regular maintenance of this product are not covered by
the warranty unless it is found to be defective by an Authorised Service Centre.
Distributed in Australia by Carbatec
Carbatec Pty Ltd
128 Ingleston Road
Wakerley, QLD 4161
Enquiries
Email: callcentre@carbatec.com.au
Freecall number: 1800 658 111
The Carbatec policy is one of continuous improvement and the company
reserves the right to alter designs, colours and specifications without notice.
Original Instructions
15

Publicité

Table des Matières
loading

Table des Matières