What To Do If - Becker Centronic VarioControl VC360-II Instructions De Montage Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Solar panel
Rated voltage
Degree of protection
Permissible ambient temperature
Dimensions (LxWxH)
Type of mounting
Problem
Tubular drive is not functioning.
The tubular drive travels in the open-
ing/closing direction in dead-man
mode.
Battery cannot be charged.
The indicator lamp LED gives a short
red flash every 10 seconds.
36 - en

What to do if...?

Program new transmitter.
Bring transmitter within range of the
radio receiver.
Press drive or stop button on trans-
mitter at least five times in the imme-
diate vicinity of the radio receiver.
Check electrical connection.
Charge battery.
Briefly press the programming but-
ton on the radio receiver to put the
control unit in operating mode.
Charge battery.
Check connection with solar panel.
Replace solar panel with a new one.
Replace battery with a new one.
The battery is low and must be
charged.
15 V DC
IP X4
-25 °C to +55°C
405 mm x 60 mm x 6 mm
Surface mounted
Remedy