Wind; Heating Power; Sky Brightness - shelyak SENTINEL PF0007 Guide Utilisateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Wind

Colors
Orange
Those threshholds can be modified by the user (in configuration panel).

Heating power

Heating follow this logic:
i) If rain or snow is detected, heating it set at 100%
ii) If external temperature is below 0°C, heating is set with a PID such as rain detector temperature sensor is around
10°C
iii) If external temperature is below 10°C and humidity is above 85%, heating is set with PID such as rain detector
temperature sensor is around 10°C
iv) If temperature is above 6°C and humidity is below 75%, heating is stopped
v) If temperature is above 15°C, heating is stopped
vi) Condition i) has higher priority than conditions ii), iii), iv) & v) ; if rain/snow detector becomes dry, conditions ii),
iii), iv) & v) are used

Sky brightness

Those thresholds can't be modified by user.
Magnitude per sec² is based on photodiode and is calculated as :
Magn = OffsetMag - ( Log10 (NbTick/sec – Dark_Ticks/sec) / Log10(2.512) )
Dark_Ticks : number of ticks in complete dark (between 0.25 and 0.45); you can calibrate your
Sentinel and change this value.
OffsetMag : photodiode gain + incoming cone size = 12.4 (fixed value).
Signal is integrated during a long exposure (1min recommanded); depending on reading frequency,
this value can be null for some time.
Sentinel – User Guide (Français / English) – DC0011C
Green
Red
Color
Green
Yellow
Orange
Red
Panneau de configuration
Wind
Wind < 10%
10% < Wind <20%
Wind> 20%
Sky brightness
Magnitude > 18
14 < Magnitude < 18
6.8 < Magnitude < 14
Magnitude < 6.8