Abicor Binzel MFS-V3 Mode D'emploi page 48

Masquer les pouces Voir aussi pour MFS-V3:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

10 Troubleshooting
Weekly
Visual inspection of the wire guide tube (7).
In case of wear, replace as follows:
 Fig. 9 on page EN-13, Step 1 to Step 4
• Pull the wire feed rolls off the full-floating axle. Undo the grub
screw (2), replace the wire guide tube (7) and secure with the grub
screw (2) again. Mount again in reverse order.
Free the wire feed rolls from wear debris as follows:
 Fig. 9 on page EN-13, Step 1 to Step 4
• Pull the wire feed rolls off the full-floating axle. Use a dust and grease-
free cloth to remove wear debris. Mount again in reverse order.
• Adjust the contact pressure if necessary.
 Fig. 9 on page EN-13, Step 8
Tab. 11
M-Drive maintenance and cleaning
10 Troubleshooting
Risk of injury and machine damage when handled by unauthorized persons
Incorrect repair work and changes of the product may lead to significant injuries and machine damage.
The product warranty will be rendered invalid if the unit is handled by unauthorized persons.
• Operating, maintenance, cleaning and repair work may only be carried out by qualified personnel (in
Please observe the attached document "Warranty". In the event of any doubts and/or problems, please
contact your retailer or the manufacturer.
NOTICE
• Please also consult the operating instructions for the welding components, such as the power source,
Fault
Cause
• Control system or component defective
Unit is not
• Gas flow controller defective or set incorrectly
ready for
operation
• M-Drive safety switch not actuated
Wire is not fed • Motor defective (master or slave)
Tab. 12
Troubleshooting
EN - 22
DANGER
Germany see TRBS 1203).
welding torch system, re-circulating cooling unit etc.
Monthly
Troubleshooting
• Replacement by qualified personnel
• Ask qualified personnel to check and set the gas flow
controller
• Inspection by qualified personnel. Close the hood if
necessary
• Use the main switch on the eBOX to cut the power to the
system
 Please see the information in the eBOX operating
instructions BAL.0388.0.
• Ask a Binzel specialist to replace the motor
• Press the reset button S9 (1), Fig. (11)
M-Drive
Every six months

Publicité

Table des Matières
loading

Table des Matières