5. FIRST COMMISSIONING

Alongside the remote control, this starter set also contains a total of 3 alarm sensors, which are pre-programmed
in your standard settings. After inserting the relevant batteries in these, they can be used immediately. The radio
remote control system must be manually added as described in Item 7.2. (Deletion of the remote control).
Note
It is advisable to firstly install the system in the condition in which it was delivered and check its functioning.
Only set individual settings (e.g. changing the PIN code or adding further components to the system) after a
successful test.
Alarm centre
The Schwaiger
"Green Guard"
automatically activated as well as in standby mode.
The 9 V battery is only a backup battery that guarantees functioning in the event of a power failure. Therefore,
use the system only via the 230 V connection and not for a longer time via the backup battery.

5.1. Removing the demo switch

This alarm system has a demo switch when delivered. This is used only for the demonstration of the display func-
tions in the sales packaging. For all further functions of the product, it is no longer required and must therefore
be removed.
For this, proceed as follows:
1. Open the battery compartment using a Phillips screwdriver.
2. Remove the plug on the upper left side of the battery compartment by carefully removing this.
3. Now you can insert a back-up battery and close the battery lid again.
4. Now connect the central unit to a 230 V plug.

5.2. Display after commissioning the central unit

After you have connected the backup battery, a beep sounds and the display lights up in different colours.
(Orange ➜ Red ➜ Green ➜ Orange)
After completing the automatic check the display switches into standby mode.
Now a
symbol is displayed and the display shows the following image:
In order to unlock the system, enter the standard PIN
Battery and network component symbol
The network component symbol
As soon as the centre is removed from the power connection, the symbol display changes automatically to a
battery symbol (also at the top right of the display).
20
ALERT
mode
flashes green every 2 seconds
centre
does not have
is always displayed when the alarm unit is directly connected to a 230V plug.
STANDBY
Situation 1
Standby
(rest) mode
Characteristics
After switching into standby mode, the
background lighting flashes yellow for
10 seconds.
an on/off switch. After connection to a 230 V plug, it is
"1-2-3-4"
and confirm this with
.