Divers; Corresponding Value For Sensors (Ntc 10K); Memory Safe - RADSON 51043 Guide D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Indications:
Error on the limiter (floor) sensor
"Er" will be blinks under the floor sensor house icons (
Lower limitation (floor sensor)
"Lo" will be blinks under the floor sensor house icons (
Higher limitation (floor sensor)
"Hi" will be blinks under the floor sensor house icons (

7 Divers

7.1 Corresponding value for sensors (NTC 10K)

To be check with an Ohmmeter, only when the sensor is
disconnected
0°C / 32°F
5°C / 41°F
10°C / 50°F
15°C / 59°F
20°C / 68°F
25°C / 77°F
30°C / 86°F
35°C / 95°F
40°C / 104°F

7.2 Memory safe

- All volatile memories (Hours, Date) are saved in case of power
supply lost during 4 hours. To have a maximum time save your
product must be plug-in during minimum 1 day.
- All others parameters (installation, program...) are saved all the
time (infinite memory save)
~32 KΩ
~25 KΩ
~19,7 KΩ
~15,6 KΩ
~12,5 KΩ
~10 KΩ
~8,1 KΩ
~6,5 KΩ
~5,4 KΩ
40
)
)
)