4
Function
C16A
The C16A is a self-centering pendulum load cell which
returns the superstructure to its stable original position
after the load application is displaced laterally, i.e. in
clined. The maximum permissible lateral displacement or
inclination (see Chapter 11, Page 33) must not be ex
ceeded as otherwise the load cells or load application
elements may be damaged. The simplest and most usual
solution here is to set up appropriate stops on the super
structure (scale platform) that must be carefully set within
the values specified for the applicable maximum capa
city.
We recommend EPO3 and C16/EPU or C16/ZOU44A
from HBM as mounting parts for the C16A, so that prob
lem-free installation is possible. The rotation stops wel
ded onto the load cell and the supplied dowel pin are also
specifically matched for this purpose (see Dimensions in
Chapter 11, Page 33).
A1460-4.0 HBM: public
Function
11