Fig. 1: Turboflotor 5000 baby ECO and single 6.0
Available spare parts: Please refer to www.aqua-medic.de.
Fig. 2: Venturi pump
4. Installation
Check that the sealing rings for the unions are in place.
Slot the holding plate for the venturi pump to one side of the skimmer. Push the pump on to the holding
plate and connect the pump to its union.
The PVC air tube should be fed to the top of the grey PVC pipe which is located between the two outlet pipes
to supply the venturi pump with air. This air tube must not hang down. It should only jut out 5 cm at the
top.
1. Lid
2. Foam cup
3. Bajonet
4. Reaction tube
5. Water inlet from the aquarium
(20 x 22 mm, ¾" hose connection)
6. Outlet to aquarium (2 x DN 40)
7. Impeller with power wheel (no picture)
8. Venturi pump
9. Water outlet valve
10. Flow control valve (2 pcs.)
11. Air injection fitting for injector nozzle (no
picture)
12. Injector nozzle
13. O-ring for injector nozzle
(pump's side)
14. O-ring for injector nozzle
(skimmer's side)
15. O-ring for outlet fitting (2 pcs.)
16. O-ring for the pressure side of the pump
17. O-ring at the outlet fitting (2 pcs.)
18. O-ring for bayonet
19. Holding plate for the pump
20. Lower fastening screws for holding plate (no
picture)
21. Upper fastening screws for holding plate (no
picture)
22. Threaded plate
23. Pressure fitting for the pump
7