Betrieb Mit Fernbedienung - Hitachi HRNM Série Manuel D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 127

BETRIEB MIT FERNBEDIENUNG

4
5. BETRIEB MIT FERNBEDIENUNG
5.1. OPTIONALE LCD-FERNBEDIENUNG PC-P2HTE
Model: PC-P2HTE
Fan speed indicator
It indicates the fan speed you have selected:
-
High/Medium/low
Indicador de vantilador Total
It indicates if Total ventilator has been selected.
-
A/C
only air conditioning
-
VENTI
only ventilation
-
A/C + VENTI
if both are selected
Operation Mode Indicator
Indicates the operation mode selected: Fan, Cool,
Heat, Dry, Auto (Cool/Heat)
Run indicator (Red Lamp)
RUN/STOP switch
MODE (Operation Mode Selection) Switch
FAN SPEED (Fan Speed Selection) Switch
Up & Down Panel Operation Switch
VENTI(Ventilator Operation) Switch
Taste LOUVER (Schwingluftklappenbetrieb)
TIME (time setting) switch
Increase and decreases the set Time for timer
operation
ON / OFF Timer (Timer Operation) Indicator
Used to activate or deactivate the timer operation
CHECK Switch
RESET (Filter Reset) Switch
After cleaning the air filter, press the "RESET" button.
The FILTER indication will disappear and the next
filter cleaning time will be set.
It also stops the run procedure.
TEMP (Temperature Setting) Switch
T.RUN (Test Run Indication)
Check (Check Indication)
These Tests appears when "TEST RUN" or "CHECK"
is being performed
ABNML (Alarm) Indicator
"FILTER" Indicator
SET TEMP (Setting Temperature) Indicator
12345S indicator (setting schedule number)
Mon Tue ... Sun (Day of the week indicator)
Indicates that central station or CS-Net is being
performed
Swing Louver Indicator
"DEFROST" is indicated
Service mode indicator. (indicates the change to
special operations)
Time indicator.
Time indicator. (indicates the programmed time).
When opening the cover, pull the cover
toward the arrow direction
NOTE:
In the case that the LOW fan speed is selected and outdoor
temperature is higher than 21°C, excessive load is given to the
compressor at heating operation.
Therefore, set the fan speed at HIGH or MEDIUM, since safety devices
may be activated.
– When the system is started after a shutdown longer than
approximately 3 months, it is recommended that the system be
checked by your service contractor.
– Turn OFF the main switch when the system is stopped for a long
period of time. Otherwise the system consumes electricity as the oil
heater remains active even though the compressor is stopped.

Hide quick links: