Measuring Frequency for ACV, ACmV and ACmA
The meter measures the frequency of a voltage or current signal
by counting the number of times the signal crosses a threshold
level each second. To measure frequency, follow the steps
below.
1. Turn the rotary switch to V, mV or mA position.
2. Press the Hz button to measure the frequency.
3. Press the Hz button or change the rotary switch position
to exit this function.
Display Hold
In the Hold mode, the meter holds the reading. To use the Hold
mode, follow the steps below.
1. Press the Hold button to activate Hold mode. The " Hold "
appears on the display.
2. Press the Hold button, Blue button, Range button or change
the rotary switch position to exit this function.
10