press the lever (33) on the cleaner gun to eliminate any remaining pressure and bring the safety catch in its locked
position (32) (Fig. 2 – position S):
- before leaving the high power cleaner unattended, even for only a short time;
- before topping up the detergent;
- after use;
• In addition, wait until the high pressure cleaner has completely cooled down before cleaning or maintenance.
• During use, do not lock the lever (33) on the cleaner gun in the open position.
• Do not remove the plug from the power outlet by pulling on the power supply cable.
• Do not put any reducers or adaptors between the electric plug and the power outlet.
• Keep the power supply cable, any extension cords, the plugs and the outlets dry. Do not touch them with wet
hands.
• Should the power supply cable be damaged, contact a Qualified Eletrician for its replacement.
• Do not cover the high pressure cleaner during operation and do not place it where there is inadequate ventilation.
• When the high pressure cleaner is used in enclosed spaces, make sure that there is adequate ventilation.
5.1 p
relImInary
procedures
• Unroll the high-pressure pipe (30) completely.
• For PW 210C - IP 2100S versions with pipe reel (11), turn the ring nut (10) anti-clockwise to release the device; unroll
the amount of pipe required by turning the reel anti-clockwise using the knob (12); turn the ring nut (10) clockwise
to block the device.
• Attach a supply pipe to the water inlet's quick connection (16) using a normal garden connector. Operation D in
Fig. 5.
• Open the tap to the water supply and make sure that there are no drips. Operation E in Fig. 5. Otherwise, prime using
an appropriate tank.
• Make sure that the main switch (1) is in the off position (the '0' position) and put the plug into the electric current
outlet. Operation F in Fig. 5.
• Turn the main switch (1) to position '1'.
• Press the cleaner gun's control lever (33) and wait for a continuous jet of water to be issued.
• Note 3: the Total Stop function is not operational in this condition because the operating pressure is less than
20 bar / 290 psi (also refer to the "Interrupting use when operating pressure is between 0÷20 bar/0÷290 psi" section).
• Turn the main switch (1) to position '0' and connect the lance pipe (21) to the cleaner gun (19). Operation G in Fig. 5.
5.2 s
tandard
operatIon
• Make sure that the nozzle head (24) is not in the position for supplying detergent (also see the "Use with detergents"
section).
• Restart the high pressure cleaner by turning the main switch (1) to position '1' and check that the spray from the nozzle
is uniform, without dripping.
• Note 4: during this restart phase, the high pressure cleaner will immediately stop operating after the initial peak, as
the Total Stop device will take effect.
• Use the cleaner gun's lever (33) to start operation of the high pressure cleaner and thus start cleaning.
• Adjust the pressure, if necessary, using the pressure adjustment control (17). Turn this knob clockwise to increase
pressure and anticlockwise to reduce pressure. The amount of pressure is shown on the pressure gauge (18)
5.3 u
se
wIth
detergents
WArNINg
• The high pressure cleaner was designed to be used with the detergents recommended by the Manufacturer. Use of
other detergents or chemicals can affect the safety of the high pressure cleaner.
Never suck up liquids, which contain solvents, petrol, diluents, acetone and fuel oil, as these products are highly
inflammable, explosive and toxic when nebulized.
• Read the instructions and warnings on the label of the detergent to be used.
• Store detergents in a safe place out of children's reach.
• Should detergent come into contact with your eyes, wash immediately with water. Contact a doctor without delay
and remember to take the container of detergent with you.
• If detergent is swallowed, do not provoke vomiting. Contact a doctor without delay and remember to take the container
of detergent with you.
• When filling the tank with detergent, take care not to spill any detergent on the high pressure cleaner. If this should
happen, wait at least 24 hours before using the high pressure cleaner so that any liquid, which may have entered
the appliance, can evaporate.
The recommended detergents, are over 90% biodegradable.
For information on how to use the detergents, refer to the instructions in the table and on the label on the container of
detergent.
(
)
hIgh