Installer Menu - Palazzetti GLH110 Notice D'utilisation

Régulateur termique.
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

6. MENU'
MAIN MENU
6.1
To enter into the main menu simply click on K2 key:
➢ Keys K3 and K4 are used to scroll through various parameters signaled by the corresponding flashing led.
➢ Press K2 key to modify (the led remains solid while value flashes).
➢ Keys K3 and K4 are used to change the parameter value.
➢ Press K2 to save the new value.
➢ Press K1 to exit without saving.
➢ Press K1 again to exit the Menu or wait 30 seconds.
Led
Low Temp. Thermostat for Fireplace Pump
Diverting Valve Thermostat on Fireplace probe
Heating Pump Thermostat on Fireplace probe
Heating Pump Thermostat on high Buffer Tank probe
Service Thermostat on Fireplace probe
Valve Thermostat for DHW priority
Temperature Delta for Heating Pump enable
Thermostat to activate Integration on Fireplace probe
Thermostat Integration Buffer Tank on High Buffer Tank Probe
Thermostat Integration Boiler on Heating Return Probe
Heating Pump Thermostat on Fireplace probe
Service Thermostat on Fireplace probe
Heating Pump Thermostat on High Buffer Tank probe
DHW Boiler Thermostat on S2
S
2
Buffer Comfort Thermostat on High Buffer Tank probe
S
3
Ambient Probe Thermostat on S3
S
S
Differential Thermostat Fireplace-Boiler DHW/Buffer
1+
3

7. INSTALLER MENU

Only QUALIFIED PERSONEL must access this MENU, because if the set parameters are changed this could make the
product completely unsuitable for the application.
To enter into the INSTALLER MENU press at the same time K2 and K4 keys for 3 seconds.
To scroll through the parameter codes use K3 and K4 keys.
To view the value of a parameter and to enter modification mode press K2 key.
To modify the value press K3 and K4 keys.
To save the new value press K2 key.
To exit without saving press K1 key.
Press K1 again to exit the Menu or wait 60 seconds.
Thermostat to close Air Damper on S1 probe
ANTIFREEZE Thermostat on S1 probe
SAFETY Thermostat on S1 probe
ALARM Thermostat on S1probe
Maximum Thermostat to enable heating pump
High Temp. Thermostat on high Buffer Tank probe
Solar Pump Activation Thermostat
ANTIFREEZE Thermostat on Collector Probe
Collector Safety Thermostat
Collector Protection Thermostat
Temperature Delta for automatic management of PWM1 in Heating
Temperature Delta for automatic management of PWM1 in DHW
Temperature Delta for automatic management of PWM2 in Heating
Buffer-Collector Differentail Thermostat
Pressure Sensor Minimum threshold
Pressure Sensor Maximum threshold
P1 Fireplace Pump Hysteresis Thermostat
P2 Deviator Valve Hysteresis Thermostat
Description
Description
Pag. 7/18
004778250 - 30/03/2020
Code
Min
Set
A01
50
20
A02
20
45
A04
20
45
A17
20
45
A09
50
20
A24
20
70
A83
2
10
A03
20
45
A19
45
20
A25
20
50
A04
20
45
A09
20
50
A17
45
20
A18
20
50
A20
20
60
b01
20
5
d01
5
20
Cod.
Min
Set
A05
75
20
A06
-10
4
A07
60
80
A08
80
90
A11
20
75
A23
20
95
A33
5
20
A34
-10
4
A35
120
60
A36
60
140
A80
20
1
A81
1
15
A82
1
20
d02
5
20
Pr01
500
3000
Pr02
3000
2000
IA01
0
2
IA02
0
2
Max
U.M.
90
[°C]
90
[°C]
90
[°C]
90
[°C]
90
[°C]
90
[°C]
20
[°C]
90
[°C]
90
[°C]
60
[°C]
90
[°C]
90
[°C]
90
[°C]
90
[°C]
90
[°C]
50
[°C]
2
[°C]
Max
U.M.
90
[°C]
10
[°C]
90
[°C]
99
[°C]
[°C]
90
95
[°C]
50
[°C]
10
[°C]
180
[°C]
180
[°C]
50
[°C]
50
[°C]
50
[°C]
2
[°C]
500
[mbar]
500
[mbar]
20
[°C]
20
[°C]
0CAR6IN019147
29

Publicité

Table des Matières
loading

Table des Matières