80 |
ATTENTION!
The figures mentioned in the chapters "GENERAL WARNINGS", "GAS MODEL INSTRUCTIONS" and "ELECTRIC
MODEL INSTRUCTIONS" are shown on the initial pages of this manual.
Before using the appliance, carefully read the instructions
provided in this booklet.
The appliance is strictly for professional use and must be
used by qualified personnel.
The Installation, start-up and maintenance of the appliance
must be carried out by qualified personnel.
All installation works must be carried out according to
EN
the law in force. The manufacturer is not responsible for
damages due to an incorrect installation, bad maintenance
or incorrect use.
LAW PROVISIONS, TECHNICAL REGULATIONS
The manufacturer declares that the appliances comply
with the EEC directives and the particular reference
regulations. The manufacturer requires the installation to
be performed according to the regulations in force.
Before installing, check that the following provisions are
met:
- building regulations and local fire prevention
measures;
- accident prevention regulations in force;
- local Gas Board regulations;
- local electric energy supply Board regulations
APPLIANCE DESCRIPTION
Sturdy steel structure with 4 feet that can be adjusted in
height.
External coating made in 18/10 chromium-nickel steel.
The serial number plate is located on the front of the
appliance and contains all the data necessary for the
connection.
MOD.
Qn
V
kW:
AND DIRECTIVES
N°:
Hz: 50/60
IPX2
GENERAL WARNINGS
INSTALLATION
Handling and transportation
The units are placed on wooden pallets to facilitate
transportation and handling by a forklift or trolley either
on the premises or when they are loaded and unloaded.
Units are packed in 3-layer sturdy cardboard boxes with
stickers and prints applied onto them for providing advice
relevant to handling. The symbols give information about
their handling, forbid the lifting the units with hooks and
storing outdoors.
It also warns operators that the packaging contains fragile
objects and indicates the vertical position that the box
must keep. It also directs the operator on opening the
packaging from downwards to upwards.
PREPARATION
Before beginning the installation, remove the packaging.
A few parts are protected with an adhesive film, which
should be removed carefully.
Remove any glue residual with the proper substances,
such as petrol; never use abrasive substances. Mount the
unit feet; the unit must be levelled; small differences of
height can be solved by adjusting the feet.
The connections to the gas and/or electric network must
be close to the appliance and easy to reach.
We recommend placing the unit under a suction hood so
that vapour can quickly evacuate. Install the unit at least
5 cm from the wall if the wall does not bear a minimum
temperature of 150° C (see fig. 1). If the unit is placed
very closely to the wall, partition walls, kitchen cabinets,
decorative walls, etc., we recommend that they are made
with a non-combustible material with a proper thermal
insulation. Pay a lot of attention to regulations concerning
fire prevention.
ATTENTION:
Air necessary for the burner combustion is equal to 2 cu
m/h per each kW of installed power.
Room ventilation
The room where the appliance is installed must be fitted
with air intakes to guarantee the correct operation of the
unit and air exchange.
Air necessary for the burner combustion is equal to 2 cu