TROUBLE SHOOTING:
Symptom
Liner does not collapse or collapses
slowly
Air leaking at retaining collar shroud
assembly
Fluid dripping from PPS™ cup
Air leaking at base of cup
Cup air supply hose slips off air supply
port at base of cup or gun regulator
Action
Check air inlet connection and pressure to gun/cup.
Check that air supply port on gun to cup is not plugged.
Check that air supply port at base of cup is not plugged.
Check cup air supply hose connection from gun to cup.
Check that retaining collar shroud assembly is tight.
Check that safety relief valve at base is in place.
Check that retaining collar shroud assembly is tight.
Verify or adjust cup pressure not to exceed a maximum
operating pressure of 10 psi (69 kPa 0.69 Bar).
Check that retaining collar shroud assembly is tight
Check that PPS™ gun adapter is fully engaged with
lid spout.
Verify or adjust cup pressure not to exceed a maximum
operating pressure of 10 psi (69 kPa 0.69 Bar).
Check that safety relief valve at base is in place
Verify or adjust cup pressure not to exceed a maximum
operating pressure of 10 psi (69 kPa 0.69 Bar).
Trim off ends or replace air supply hose PN 16123.
English - 6