▶ Set the forward / reverse selector switch to forward or reverse rotation.
6.2 Switching on
▶ Press the control switch.
➥ Speed of rotation is regulated by the distance the control switch is
pressed in.
6.3 Screwdriving
CAUTION
Risk of injury by damaged workpieces! Screws or workpiece can be
damaged if torque is too high. This presents a risk of injury.
▶ Make sure that screws and workpiece are suitable for the torque produced
by the tool.
▶ Set the forward/reverse switch to the desired direction of rotation.
➥ Be sure to use the correct adapter.
6.4 Switching off
▶ Release the control switch.
6.5 Removing the accessory tool
1. Set the forward/reverse switch to the middle position or remove the
battery from the power tool.
2. Pull the chuck ring forward and hold it in this position.
3. Pull the bit out of the chuck and let go of the ring.
7
Care and maintenance
WARNING
Risk of injury with battery inserted !
▶ Always remove the battery before carrying out care and maintenance
tasks!
Care and maintenance of the tool
• Carefully remove stubborn dirt.
• Clean the air vents carefully with a dry brush.
• Use only a slightly damp cloth to clean the casing. Do not use cleaning
agents containing silicone as these can attack the plastic parts.
Care of the Liion batteries
• Keep the battery free from oil and grease.
• Use only a slightly damp cloth to clean the casing. Do not use cleaning
agents containing silicone as these may attack the plastic parts.
• Avoid ingress of moisture.