Installation; Considerations Before Installing Hood; Parts Included - Thermador Professional PH Série Manuel D'installation

Masquer les pouces Voir aussi pour Professional PH Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation

Considerations Before
Installing Hood

Parts Included

Hood Canopy
Halogen bulbs, installed
Filters (2, 3, or 4 depending on model and size)
Metal Transition with backdraft damper installed
Fasteners
Remote Blower ("pigtail") Adaptor
Wooden Strip used for Hood Mounting Bracket
Wire Nuts
2 - 175W PAR-38 Heat Lamps or
2 - 250W PAR-40 Heat Lamps (on some models)
Use & Care Manual / Installation Instructions
Registration Card
Parts NOT Included
Duct Tape
1/2" Conduit
Ventilator — The hood can be installed with blower
models VTN630C, VTN1030C, VTI610D, VTI1010D,
VTR630D, VTR1030D, or VTR1330E.
Optional duct cover, 6" DC(30,36, 48)US or
12" DCT(30, 36, 42, 48)US height (available for
purchase separately).
Optional Remote Control (available for purchase
separately with select models).
Optional Keep Hot Shelf, KHS(30, 36, 42, 48)QS
(available for purchase seperately with hood widths
30", 36", 42", and 48")
1. For the most efficient air flow exhaust, use a straight
run or as few elbows as possible.
2. Do not use flex ducting.
3. COLD WEATHER installations should have an
additional backdraft damper installed to minimize
backward cold air flow and a non-metallic thermal
break to minimize conduction of outside temperatures
as part of the ductwork. The damper should be on the
cold air side of the thermal break. The break should be
as close as possible to where the ducting enters the
heated portion of the house.
4. Hood installation height above a cooktop or range can
vary. To obtain the necessary installation height above
a Thermador Professional Cooktop or Range, consult
the appliance's installation manual.
* For indoor grill installations, Thermador
recommends a minimum of 36" clearance and
remote and inline blowers only (VTR630D,
VTR1030D, VTR1330E, VTI610D, or
VTI1010D).
5. Remote blowers require a five wire installation.
6. Make-Up Air: Local building codes may require the use
of make-up air systems when using ducted ventilation
systems greater than specified CFM of air movement.
The specified CFM varies from locale to locale. Consult
your HVAC professional for specific requirements in
your area.
7. Refer to Remote Control Installation Instructions if
applicable.
English 3