C. Programming
— DO NOT OPEN THE DOOR —
The display window MUST show "0" before programming.
Programming Memory Pads for Single Stage Heating:
Example: To program 30 seconds at 500 W for Memory Pad 5
PAD
1.
2.
3.
4.
5.
NOTE: • Program the remaining Memory Pads as desired by repeating steps 1 to 5. You may insert up to
10 memory programs.
• When the Program indicator "
erased by pressing the Stop/Reset Pad.
NE-1037_EYG.indb
16
How to Operate
• Press the Program Pad.
Note:
• If no "
" Indicator appeared on display,
"Program Lock" should be cancelled.
(See page 19)
• Press the Memory Pad 5. The pad number and the
previously selected time and power level will appear
in the display.
• The pad number and Stage Heating Indicator will
appear in the display again.
• Press the Power Level Pad twice. The Memory
Pad number will go out.
• Press Memory Pads 3 and 0.
• Press the Program Pad again. You have completed
programming the selected Memory Pad for single
stage heating. Double heating time for multiple
portion heating was automatically set.
• 2 seconds later, the time and power level setting
you programmed will appear in the display.
• 2 seconds later, Double Quantity (x 2) Heating
Indicator and then the double heating time will
appear in the display.
• 2 seconds later, the display will show "0".
The Memory Pad 5 is now programmed for heating
- 30 seconds at 500 W.
" is blinking, the program can be cancelled and/or the pad number
- 16 -