English
Type
Optoelectronic infrared reflex pulse sensor for modulator disc
Usability
Single-jet bulk water meters, Type ETK-M-C, DN 50,65,80,100 with 100 l/pulse
Notes
To ensure the correct mounting of the module, position the module's cam into the groove of the register
hood and clip-on the module
If necessary, secure the hood against unauthorized disassembly with the enclosed seal wire and snap
seal
Technical specifications
Model
In black housing NOT potted
Protection class
IP 65
Cable length
1,5 m
Mark
CE
Working tempe-
0,1 ... +60 ºC
rature
Lithium battery 3.6V AA, up to 10
Power supply
years lifetime
Flexible YTLY 4 x 0.14mm² cable
Cable type
without shielding
Green = Ground (GND)
White = Output 1
Colour of con-
ductor
Brown = Output 2
Yellow = Alarm
IB - Balanced pulse output"
PR - Standard pulse output (like
mecanical Reed-Switch)
Output mode
WP - Pulse only forward
Combination
A1 / A
WS - Pulse only backward
AW - Error massage
SK - Flow direction
output 1: IB - Balanced pulse
output
Standard Mode
output 2: PR - Standard pulse out-
ZRI
put (like mecanical Reed-Switch)
ZENNER International GmbH & Co. KG
Römerstadt 6
D - 66121 Saarbrücken
Telephone +49 681 99 676-30
Telefax
+49 681 99 676-3100
Technical specifications
Output type
Open Collector
30 Ohm (open) /
Output resistance
200 MOhm (closed)
Pulse voltage
100 V
Impulse current
170 mA
4Hz (250ms - stable pulse width;
Max. output
unstable pulse width with higher
frequency
frequency)
WIRING DIAGRAM
Wiring diagramltplan
E-Mail
info@zenner.com
Internet www.zenner.com
1. White
Programmable pulse output 1
2. Brown
Programmable pulse output 2
3. Yellow
Alarm reading con guration etc.
4. Green
Mass
3