English
Type
Optoelectronic infrared reflex pulse sensor for modulator disc
Usability
Single-jet bulk water meters, Type ETK-M-C, DN 50,65,80,100 with 100 l/pulse
Notes
■
To ensure the correct mounting of the module, position the module's cam into the groove of the register
hood and clip-on the module
■
If necessary, secure the hood against unauthorized disassembly with the enclosed seal wire and snap
seal
Technical specifications
Model
In black housing NOT potted
Protection class
IP 65
Cable length
1,5 m
Mark
CE
Working tempe-
0,1 ... +60 ºC
rature
Lithium battery 3.6V AA, up to 10
Power supply
years lifetime
Flexible YTLY 4 x 0.14mm² cable
Cable type
without shielding
Green = Ground (GND)
White = Output 1
Colour of con-
ductor
Brown = Output 2
Yellow = Alarm
IB - Balanced pulse output"
PR - Standard pulse output (like
mecanical Reed-Switch)
Output mode
WP - Pulse only forward
Combination
A1 / A
WS - Pulse only backward
AW - Error massage
SK - Flow direction
output 1: IB - Balanced pulse
output
Standard Mode
output 2: PR - Standard pulse out-
ZRI
put (like mecanical Reed-Switch)
ZENNER International GmbH & Co. KG
Römerstadt 6
D - 66121 Saarbrücken
Telephone +49 681 99 676-30
Telefax
+49 681 99 676-3100
Technical specifications
Output type
Open Collector
30 Ohm (open) /
Output resistance
200 MOhm (closed)
Pulse voltage
100 V
Impulse current
170 mA
4Hz (250ms - stable pulse width;
Max. output
unstable pulse width with higher
frequency
frequency)
WIRING DIAGRAM
Wiring diagramltplan
E-Mail
info@zenner.com
Internet www.zenner.com
1. White
Programmable pulse output 1
2. Brown
Programmable pulse output 2
3. Yellow
Alarm reading con guration etc.
4. Green
Mass
3