3. TECHNICAL DATA
Maximal inlet pressure P1=
Model
DC280-1,5
DC380-1,5
DC280-4
DC380-4
DC280-10
DC380-10
DC280-16
DC380-16
DC280-35
DC380-35
Nominal flow (*)
Operating temperature
Storage temperature
Flow coefficient :
Input connections
Output connections
Gauges
Installation torque for Inlet and Outlet
connector NPT1/4M
Safety device
Upstream filter
TECHNICAL MANUAL
REGULATOR
This DC280/380 is a component designed to be used in an installation of pure
gas. The final manufacturer is responsible for preparing appropriate and adequate
instructions and warnings for the final user.
200 bar (2900 psig) for models DC280
300 bar (4350 psig) for models DC380
Outlet pressure adjustable between
0,2 to 1,5 bar (3 to 22 psi)
0,4 to 4 bar (5,8 to 58 psi)
1 to 10 bar (14,5 to 145 psi)
1 to 16 bar (14,5 to 232 psi)
3 to 35 bar (44 to 508 psi)
Flow for which i (coefficient of irregularity according to ISO2503) ≤ 20% and R
(pressure rise coefficient according to ISO2503) ≤ 20%.
From –40°C to +60°C (from –40°F to 140°F)
Between –40°C to +70°C (between –40°F to 158°F)
Cv= 0,1 (Kv= 0,09)
2 x NPT1/4 F whose one with 1 plug
2 x NPT1/4 F
1 safety valve on transfer connection (MP)
Exter Diameter. = 50mm (2 in), thread NPT1/4 M
¤ for models DC280&380 = 1 gauge HP and 1 gauge BP
16 Nm + sealing tape PTFE
This unit has a non-collectable safety valve which only protects
the regulator and never the system downstream of the latter
For models DCL280&380 =1 bronze filter, gas filtration threshold of
98% of the particles stop of 45µm.
For models DCI280&380 =1 stainless steel 316L filter, gas filtration
threshold of 98% of the particles stop of 48µm.
This filter only protects the regulator and never the system
downstream.
For models DCL280&380
DC280 et DC380
NT 0337
Révision : 2
30/06/2015
Page 16 / 24
Nominal flow(*)
3
3 Nm
/h (50 LPM) of N
3
3 Nm
/h (50 LPM) of N
3
8 Nm
/h (133 LPM) of N
3
8 Nm
/h (133 LPM) of N
3
30 Nm
/h (500 LPM) of N
3
30 Nm
/h (500 LPM) of
3
50 Nm
/h (833LPM) of N
3
50 Nm
/h (833 LPM) of N
3
75 Nm
/h (1250 LPM) of N
3
75 Nm
/h (1250 LPM) of N
For models DCI280&380
2
2
2
2
2
2
2
2
2