5. MAINTENANCE

5.1
Cleanliness
Ensure that the cleanliness of this product is maintained. In order to do this :
Regularly clean the outside of the pressure reducer with lint-free cloth and alcohol (all other
cleaning methods are prohibited).
The indicator pressure of gauges may have incompatibilities with isopropyl alcohol. When cleaning
these, use ethyl alcohol (ethanol).
The inside of the pressure reducer must not be cleaned (this operation is carried out at the factory).
However, it is recommended to flush the pressure reducer with a neutral gas before putting it into
service, or after a long storage period.
5.2
Checks
Each time the cylinder is changed:
Check that the pressure reducer shows no visible signs of damage.
Clean the pressure reducer using the procedure described above.
After each assembly, check that the regulator operates correctly.
The correct operation of the pressure reducer is to be regularly checked by the user (at least once a
month). In case of doubt or incorrect operation, replace the pressure reducer by a new one. A pressure
reducer that has discharged an excessive flow must be replaced.
The warranty foreseen in our general conditions of sale does not cover the following :
Repair or replacement due to normal wear or damage during routine maintenance.
Damage to components whose fragility is for technical reasons unavoidable and determined by
product design.
Damage from not following recommended maintenance and procedures, as outlined in this
instruction manual.
Damage arising from modifications not included in the procedures in this instruction manual.
Damage resulting from the use of an unauthorised part, supplied, manufactured or modified by
procedures not included in this instruction manual.
WARNING
!
Maintenance, repairs and reconditioning of the DC280/380 are under the responsibility of the user or the
operator. Anyone attempting to maintain, repair or conditioning the regulator must be thoroughly familiar
with Standard CGA E4, issued by the "COMPRESSED GAS ASSOCIATION" and all other standards
and regulations referenced therein.
According to this norm maintenance, repair and/or reconditioning shall be performed by properly trained
personal.
In case of incident or complaint, the user has to send back the supposed defective product to the
manufacturer SMT, securely packed. In order to preserve the warranty, the user will not execute any
intervention on the product (disassembling, repair, modification...) without our written agreement.

5.3 Safety instructions

Only personnel trained and qualified must be in charge of intervening on the module.
Never intervene on pressurized equipment.
Apply scrupulously the maintenance instructions described in the maintenance manual.
Use only equipment compatible with the nature of the gases, risks of fire or explosion may result
TECHNICAL MANUAL
REGULATOR
Failure to follow the installation instructions and handling instructions may cause an
accident or personal injury, for which SMT declines any responsibility.
DC280 et DC380
NT 0337
Révision : 2
30/06/2015
Page 21 / 24