Installation and Operating Instructions
EN
NOTE
Controller KWL 45 BEU
9 . Load from file
In order to load a saved configuration, press Button
Select the saved configuration or file in the destination folder and click "Open".
10 . Save to file
In order to save a configuration to a PC/Laptop, press Button
nistered. The file is saved as a .evc file.
The configuration is not automatically saved on the controller!
11 . Configuration fields
All available functions that can be configured.
12 . Display Total operating hours
Displays the total operating hours of the controller.
13 . Display Operating hours
Displays the operating hours since the last reset.
5 .1
Configuration via controller
The KWL EC 45 unit can be configured using the EcoVent Verso software or the KWL 45 BEU controller.
Ventilation stage button
– Selection / setting of ventilation stages
Operating mode button
– Adjustment / setting of operating mode
In order to start configuration mode, hold down both controller buttons
As soon as configuration mode is active, this will be indicated by LED 1 and LED 7 flashing.
The desired configuration or setting can be selected with button
up (see table below).
The configuration mode will automatically close if not button is pressed within 30 seconds . Saving is not pos-
sible!
Example:
The function external contact is to be set/changed:
Hold down both controller buttons
Release buttons when LED 1 and LED 7 are flashing.
button 1x → LED 2 lights up
Press
As soon as the function is selected, the setting can be changed using the
operating mode
button.
button 1x → LED 6 lights up
Press
button 2x → LED 7 lights up
Press
button 3x → LED 6 / 7 lights up
Press
button 4x → LED 8 lights up
Press
LED menu displays (* = factory settings)
1 . Filter change
LED 1 / 6
LED 1 / 7
3 months
6 months*
M
Ø
.
Æ
+
for 8 seconds.
External contact
Þ
Cross-ventilation
Þ
Supply air mode
Þ
Ventilation stage 0
Þ
Ventilation stage 5
Þ
LED 1 / 6 / 7
LED 1 / 8
9 months
12 months
M
M
9
. The destination folder or file name can be self-admi-
+
for 8 seconds.
or
, until the corresponding LED code is lit
LED 5
LED 4
LED 3
LED 2
LED 1
LED colour coding:
LED 6 = green
LED 7 = yellow
LED 8 = blue
M
LED 8
LED 7
LED 6