Replacing A Fuse; How To Store The Heater - Shizuoka Seiki VAL6 Daystar Manuel D'utilisation

Masquer les pouces Voir aussi pour VAL6 Daystar:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4
Disconnect the red wire of overheat protec-
tion at the back of the burner base.
Unscrew three nuts and pull out the burner
5
unit.
6
Replace with a new nozzle by using the
provided nozzle spanner.
Nozzle Spanner

■ Replacing a fuse

1
Unscrew two screws and take the burner
cover off.
2
Replace with a new fuse on the board.
3
Put the burner cover back with two screws
removed.
6

How to store the heater

CAUTION
When you store the heater, please disconnect the power plug from the extension cord and/or the
AC outlet and store the heater indoors where it is less humid.
• Do not store the fuel over summer months for use during next heater season. Using old fuel could damage the heater.
14
4
Nozzle
• If the heater is stored or not used for an extended period of time, empty the fuel tank to
help prevent fuel leakage and other possible fire dangers.
Observations
7
Tighten the nozzle using the nozzle span-
ner until the nozzle is fixed.
Observations
• Be careful not to touch electrodes
8
Put the burner unit back with three nuts re-
moved.
9
Put the red wire back.
10
Attach the return hose to the air vent valve
and the suction pipe to the fuel pump with
the nuts unscrewed.
11
Put the burner cover back with two screws
removed.
Fuse