How To Connect The Control Device - Shizuoka Seiki VAL6 Daystar Manuel D'utilisation

Masquer les pouces Voir aussi pour VAL6 Daystar:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

■ Ignition Procedures
• To make sure the heater is ignited, please do not leave the heater until you confirm that it is burning and otherwise func-
tioning properly.
1
Use the fuel gauge to check if the fuel is
sufficiently filled up in the tank.
2
Turn "ON" the operating switch, and the
heater will ignite in about 5 seconds.
If ignition fails, try again as follows
First, switch the operating switch "OFF",
and try the ignition sequence again.
■ Shut-Down Operation
CAUTION
• Before you disconnect the power plug from the AC outlet, please make sure that the fan motor is stopped.
• Never disconnect the power plug while the heater is operating, it will cause nozzle to be clogged.
Turn "OFF" the operating switch, and the
heater flame will be extinguished, then the
cooling operation will also automatically
stop after about five (5) minutes.
● If the heater is used for only a short period of time
after refueling, air inside of the fuel pipe may cause
the flame to flicker when the heater shutting down.
This is not abnormal.

3-3. How to connect the Control Device

To connect the control device
1
Uncouple the terminals (A) attached to the
tip of white wires that come out of the burner base.
2
Connect both male and female terminals,
which are uncoupled, to the connectors (B) of
control device.
1
Observations
• After the operation is shut down, please make sure that the flame is completely extin-
guished before leaving the heater unattended or moving or storing it.
Observations
Operating Switch "ON"
ON
OFF
Misfire
Operating Switch "OFF"
ON
OFF
Misfire
Operating Switch "OFF"
ON
OFF
Misfire
Terminals (A)
To Control Device
Connectors (B)