mundoclima MUCSR-12-H11 Manuel D'installation Et L'utilisauter page 218

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 86
Indoor unit(s)
Model(s):
Outdoor unit
Outdoor side heat exchanger of air conditioner: Air
Indoor side heat exchanger of air conditioner: Air
Type: compressor driven vapour compression
If applicable: driver of compressor: electric motor
Item
Symbol
Rated cooling
Prated,c
capacity
Declared cooling capacity for part load at given outdoor
temperatures Tj and indoor 27°/19 °C (dry/wet bulb)
Tj = 35℃
Pdc
Tj = 30℃
Pdc
Tj = 25℃
Pdc
Tj = 20℃
Pdc
Degradation
co-efficient for air
Cdc
conditioners (*)
Off mode
POFF
Thermostat-off
PTO
mode
Capacity control
Sound power
LWA
level,indoor/outdoor
If engine driven:
NO
Emissions of
x (**)
nitrogen oxides
GWP of the
refrigerant
SALVADOR ESCODA SA
NÁPOLES 249 P1
Contact details
08013 BARCELONA (SPAIN)
+34 93 446 27 80
Information requirements for air-to-air air conditioners
Value
Unit
15,3
kW
15,300
kW
11,101
kW
7,378
kW
3,855
kW
2,50
Power consumption in modes other than 'active mode'
0,012
kW
0,025
kW
Other items
variable
65/73
dB
mg/kWh
x
fuel
input GCV
kg CO2 eq
675
(100 years)
218
MUCSR-60-H11T-I
MUER-60-H11T-E
Item
Symbol
Seasonal space cooling
energy efficiency
Declared energy efficiency ratio or gas utilisation
efficiency/auxiliary
energy factor for part load at given outdoor temperatures Tj
Tj = 35℃
EERd
Tj = 30℃
EERd
Tj = 25℃
EERd
Tj = 20℃
EERd
Crankcase heater mode
Standby mode
For air-to-air air
conditioner: air flow
rate, outdoor
measured
Value
Unit
ηs,c
249,0
%
297,000
%
460,000
%
728,000
%
1236,000
%
PCK
0,000
kW
PSB
0,012
kW
7500
m3/h