Setting the duration of treatment

1
2
3
Figure: Timer
The operating time can be determined by setting the
integrated timer to a preset period of time.
Once this time has elapsed, the device will switch off
automatically.
The timer is equipped with two selector switches for
setting the time units (3 and 6) as well with a central
turn-switch (4) which can be used to set the numeri-
cal values.
Time units
The time unit is determined using the right selector
switch (6). You can select between setting the min-
utes and hours. The selected time unit is shown in
a display field (5). Please use a screwdriver to make
settings.
Minutes: Turn the selector switch to the left.
Hours: Turn the selector switch to the right.
Multiplier
The left selector switch (3) is used to determine
whether the indicator scale should be used for 5 or
50 time units. Please also use a suitable screwdriver
here.
If the selector switch is in the left position, the multi-
plier amounts to 1. The scale (2) displays a range of
0 - 5 time units (minutes or hours).
If the selector switch is in the right position, the mul-
tiplier amounts to 10. The scale displays a range of
0 - 50 time units.
B-5
Time duration
The actual numerical value (time duration) can be set
using the central turn-switch (4) as described in the
following. It can be read off the scale (2).

Carrying out the odour neutralisation

4
When carrying out a cleaning cycle, please proceed
as follows:
5
1.
6
2.
3.
4.
5.
6.
7.
During the ongoing cleaning cycle, small amounts of
ozone (O
lower the intensity of the singlet oxygen production
and/or put the device out of operation.
Operating manual – AirgoPro 8 odour neutraliser
Place the AirgoPro 8 in the centre of the
room.
Make sure that the device and the connect-
ing cables are undamaged!
Connect the power cable and connect the
device to the power supply. Observe the
technical parameters.
Set the timer to the desired duration of treat-
ment.
Now, set the cleaning intensity. Depending
on the odour intensity, you can choose be-
tween 5 levels. (see "Setting the cleaning
intensity")
Set the ventilation speed (see "Setting the
ventilation level").
Switch the device on afterwards. The control
indicator will light up. The cleaning cycle will
start immediately. Once the preset period of
time has elapsed, the odour neutraliser will
switch off automatically.
) may be produced. In this case, gradually
3
Warning!
Risk of injury due to ozone!
The odour neutraliser must be
put out of operation as soon as
you perceive a smell of ozone
during the cleaning cycle. Thor-
oughly ventilate the room.
EN