8
Wiring of the standard device
Control terminals
Encoder
Terminal X8
9400SSP000X8
Note regarding the connection of motor temperature sensors to "KTY"
Standard setting: KTY 83−110
ƒ
Parameterisation also supports: PT1000 and PT10000/2 PTC's
ƒ
– HighLine from SW−V14.xx onwards
– ServoPLC from SW−V08.xx onwards
76
Pin
Description
TTL
1
A
2
GND
3
B
4
V
CC
5
Z
n. c.
6
7
−KTY
8
n. c.
9
/A
10
n. c.
11
/B
12
n. c.
13
/Z
14
+KTY
n. c.
15
l
Cable EYF001...
1 V
1 V
SS
SS
Hiperface
Cos
Cos
GND
GND
Sin
Sin
V
V
CC
CC
Z
+RS485
n. c.
n. c.
−KTY
−KTY
n. c.
n. c.
Ref Cos
Ref Cos
n. c.
n. c.
Ref SIN
Ref SIN
n. c.
n. c.
/Z
−RS485
+KTY
+KTY
n. c.
n. c.
EYF002...
1 V
SSI
SS
EnDat 2.1
Cos
n. c.
GND
GND
SIN
n. c.
V
U
CC
S
Data (Z)
Data +
n. c.
n. c.
−KTY
−KTY
Clock
Clock +
Ref Cos
n. c.
−Sense
n. c.
Ref SIN
n. c.
+Sense
n. c.
/Data (/Z)
Data −
+KTY
+KTY
/Clock
Clock −