DIAPHRAGME
VENTILATEUR
BASE
1.
DECONNECTER LA MACHINE DE L'ALIMENTATION PRINCIPALE. RETIREZ LE COUVERCLE
ET LES PANNEAUX LATERAUX.
2.
RETIREZ LA PLAQUE DE'OBTURATION.
3.
PLACEZ L'HYDROSTAT TEL QU'INDIQUE A L'AIDE DES 4 VIS M4 FOURNIES.
4.
FIXEZ LE TUBE FLEXIBLE AU DIAPHRAGME DU VENTILATEUR ET A LA BASE TEL
QU'INDIQUE A L'AIDE D'UN ECROU ADAPTATEUR.
5.
RETIREZ LE SHUNT ROUGE SUR LE BORNIER ELECTRIQUE ET REMPLACEZ-LA PAR LES
FILS DE L'HYGROSTAT.
6.
REPLACEZ LE COUVERCLE ET LES PANNEAUX LATERAUX. INSTALLATION TERMINEE.
INSTALLATION DU KIT HYGROSTAT
RETIREZ COUVERCLE ET
PANNEAUX LATERAUX
RETIREZ LA
PLAQUE
D'OBTURATION
BORNIER
ELECTRIQUE
CABLE POUR
HYGROSTAT
ENLEVER LE
SHUNT ROUGE
ROSE
BLANC
CONNEXIONS BORNIER
ELECTRIQUE
Page 18
DECONNECTER LA
MACHINE
ON
OFF
00000.00
VIS M4
VERS LA
BASE
DIAPHRAGME
VENTILATEUR