Tools and Parts
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools needed
Level
■
Drill
■
Drill with 1¼" (3.0 cm), 3/16" (4.8 mm), 1/8" (3.0 mm), and
■
5/16" (7.9 mm) drill bits
Pencil
■
Wire stripper or utility knife
■
Tape measure or ruler
■
Pliers
■
Caulking gun and weatherproof caulking compound
■
Vent clamps
■
Jigsaw or keyhole saw
■
Flat-blade screwdriver
■
Metal snips
■
Phillips screwdriver
■
Metric hex key set
■
Parts needed
Home power supply cable
■
1/2" (1.3 cm) UL listed or CSA approved strain relief
■
3 UL listed wire connectors
■
1 wall or roof cap
■
Metal vent system
■
Parts supplied
Remove parts from packages. Check that all parts are included.
Hood canopy assembly with ventilator and light bulbs
■
installed
3¼" x 10" (8.3 x 25.4 cm) rectangular vent connector
■
2 metal grease filters for 30" (76.2 cm) model
■
3 metal grease filters for 36" (91.4 cm) model
■
T20
Torx
adapter
®
®†
■
4 - 5 x 45 mm mounting screws
■
6 - 4.5 x 13 mm screws
■
3 - 4 x 8 mm screws
■
4 - 10 x 50 wall anchors
■
†®TORX and T20 are registered trademarks of Acument Intellectual Properties, LLC.
4
INSTALLATION REQUIREMENTS
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the range hood. It is the
installer's responsibility to comply with installation clearances
specified on the model/serial rating plate. The model/serial rating
plate is located behind the left filter on the rear wall of the vent
hood.
Canopy hood location should be away from strong draft areas,
such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance.
Grounded electrical outlet is required. See "Electrical
Requirements" section.
The canopy hood is factory set for venting through the roof or
wall.
All openings in ceiling and wall where canopy hood will be
installed must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home
Construction and Safety, Title 24, HUD, Part 280) or when such
standard is not applicable, the standard for Manufactured Home
Installation 1982 (Manufactured Home Sites, Communities and
Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local
codes.
Product Dimensions
Front View
2⁹⁄₁₆"
(6.5 cm)
³⁄₈"
(1.0 cm)
7½"
(19.0 cm)
2"
(5.1 cm)
30" (76.2 cm)
36" (91.4 cm)
29¹⁄₈" (74.0 cm): 30" (76.2 cm) models
35¹⁄₈" (89.2 cm): 36" (91.4 cm) models
23" (58.4 cm)
12"
(30.5 cm)
10"
(25.4 cm)