4. Repeat steps 1-3 for the underside of the top of the cabinet.
Cabinet cutouts
*From wall, not cabinet frame
Wall Venting Under Cabinet
To make a 3½" x 10½" (8.9 cm x 26.7 cm) rectangle in the
wall:
1. Make 2 lines by measuring 3/8" (9.5 mm) and 3
down from underside of cabinet and mark on the centerline
on the back wall.
2. Mark lines 5¼" (13.3 cm) to the right and left of the centerline
on the wall.
Use saber or keyhole saw to cut a rectangular opening in the wall
for the vent.
Cabinet
front
2¾"
(7.0 cm)
6¾"
(17.1 cm)
(13.3 cm)
3. Lift the range hood up under cabinet and determine final
location by centering beneath cabinet. Mark on the underside
of cabinet the location of the 4 keyhole mounting slots on the
range hood. Set range hood aside on a covered surface.
A
A. Keyhole slot
4. Use 1/8" (3 mm) drill bit and drill 4 pilot holes as shown.
A. Drill pilot hole.
5. Install the 4 - 4.5 x 13 mm mounting screws in pilot holes.
Leave about 1/4" (6.4 cm) space between screw heads and
cabinet to slide range hood into place.
8
*³⁄₈" (1.0 cm)
*3⁷⁄₈"
5¹/₄"
(9.8 cm)
(13.3 cm)
5¹/₄"
(13.3 cm)
/
" (9.8 cm)
7
8
Centerline
5
"
5
"
¹⁄₄
¹⁄₄
(13.3 cm)
A
¹⁄₄"
(6.4 mm)
For Wall Installations:
1. Determine and mark the centerline on the wall where the
canopy hood will be installed.
2. Select a mounting height between a minimum of 30"
(76.2 cm) and a suggested maximum of 36" (91.4 cm) above
the range to the bottom of the hood. Mark a reference line on
the wall.
3. Using 2 or more people, center the hood on the vertical
centerline, then align the bottom of the hood with the
horizontal reference line marked on the wall.
A
D
A. Horizontal reference line
B. Vertical centerline
C. Mounting height
D. Cooking surface
4. Mark centers of the fastener locations to the wall. Set range
hood aside on a covered surface.
A
A. Keyhole slot
IMPORTANT: All screws must be installed into wood. If there
is no wood to screw into, additional wall framing supports
may be required.
5. Drill 3/16" (4.8 mm) pilot holes at all locations where screws
are being installed into wood.
A. Drill pilot hole.
6. Install the 2 - 5 x 45 mm mounting screws. Leave a 1/4"
(6.4 mm) gap between the wall and the back of the screw
head to slide range hood into place.
¹⁄₄"
(6.4 mm)
7. Determine and make all necessary cuts in the wall or ceiling
for the vent system. Install the vent system before installing
the hood. See "Venting Requirements" section.
C
B
X
A