10. Lubrication
Lubricate the following sliding surfaces once a month
to keep the power tool in good operating condition for a
long time.
Use of machine oil is recommended.
Oil supply points:
* Rotary portion of hinge
* Rotary portion of holder (A)
* Rotary portion of vise assembly
11. Cleaning
Periodically remove chips and other waste material
from the surface of the power tool with a damp, soapy
cloth. To avoid a malfunction of the motor, protect it from
contact with oil or water.
If the laser line becomes invisible due to chips and the
like adhered onto the window of the laser marker's light-
emitting section, wipe and clean the window with a dry
cloth or a soft cloth moistened with soapy water, etc.
Clean the machine, duct, lower guard, by blowing with
dry air from an air gun or other tool. (Fig. 36)

SELECTING ACCESSORIES

The accessories of this machine are listed on page 278.
CAUTION
Repair, modifi cation and inspection of HiKOKI Power
Tools must be carried out by a HiKOKI Authorized
Service Center.
Especially laser device should be maintained by the
authorized agent by laser manufacturer.
Always assign the repair of laser device to HiKOKI
Authorized Service Center.
In the operation and maintenance of power tools, the
safety regulations and standards prescribed in each
country must be observed.
GUARANTEE
We guarantee HiKOKI Power Tools in accordance with
statutory/country specifi c regulation. This guarantee does
not cover defects or damage due to misuse, abuse, or
normal wear and tear. In case of complaint, please send
the Power Tool, undismantled, with the GUARANTEE
CERTIFICATE found at the end of this Handling instruction,
to a HiKOKI Authorized Service Center.
NOTE
Due to HiKOKI's continuing program of research and
development the specifi cations herein are subject to change
without prior notice.
Information concerning airborne noise
The measured values were determined according to
EN62841 and declared in accordance with ISO 4871.
Measured A-weighted sound power level: 105 dB (A).
Measured A-weighted sound pressure level: 92 dB (A).
Uncertainty K: 3 dB (A).
Wear hearing protection.
The declared noise emission value has been measured in
accordance with a standard test method and may be used
for comparing one tool with another;
It may also be used in a preliminary assessment of exposure.
WARNING
○ The noise emissions during actual use of the power tool
can diff er from the declared values depending on the
ways in which the tool is used especially what kind of
workpiece is processed.
○ Identify safety measures to protect the operator that
are based on an estimation of exposure in the actual
conditions of use (taking account of all parts of the
operating cycle such as the times when the tool is
switched off and when it is running idle in addition to the
trigger time).
Information for power supply system to be used with
electric tools provided with rated voltage 230 V~
Switching operations of electric apparatus cause voltage
fl uctuations.
The operation of this electric tool under unfavorable mains
conditions can have adverse eff ects to the operation of other
electric apparatus.
With a mains impedance equal or less than 0.29 Ohms there
will probably be no negative eff ects.
Usually, the maximum permissible mains impedance will
not be exceeded when the branch to the power outlet is fed
from a junction box with a service capacity of 25 ampere or
higher.
In case of power failure, or when the power plug is pulled
out, immediately return the switch to OFF position. This
prevents an uncontrolled restart.