Installation And Connection; Installation/Assembly; Electrical Connection - Salvis Gastroline PSOWB084045 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

en
8.

Installation and connection

D When transporting by hand: Note the weight of the appliance and wear protective gloves!
D Follow the local technical regulations for kitchens.
D Installations must be carried out in accordance with the manufacturer's instructions, following
accepted technical regulations.
D Let customer services set up and install the appliance and provide instruction.
8.1

Installation/assembly

D Installation/assembly
− horizontally and vibration free,
− not on heated and burnable surfaces,
− not against flammable walls,
− not over thermal equipment, such as cooking, roasting, and deep‐frying equipment!
D Keep to the appropriate distances to prevent the walls and table tops from overheating:
− Between heated bridge and walls = 10 cm.
− Between heater and table top = 35 cm (version with tubular heating element) or 40 cm
(version with infrared lamp).
. Remove protective foil from appliance. Remove residual adhesive with cleaner's naphtha.
8.2

Electrical connection

D Electrical connection must be carried out by a qualified electrician‐
− according to the applicable VDE 0100 directives
− and the directives of the responsible power supply company.
D For safety reasons, we recommend installing a 10 mA residual‐current circuit breaker
(RCCB).‐ >
D Make sure that the earth conductor system for the in‐house electrical installation is installed
according to regulations.
D The flexible mains connection must be at least H 07 RN‐F.
D The mains plug must be easily accessible with devices with mains plugs!
D On appliances with a fixed connection, an electrical switch (main switch) must be connected
between the appliance and power source and be easily accessible! The switch must effec­
tively disconnect the appliance at all poles from the mains. The contact opening must be at
least 3 mm.
D Observe the data on the type plate when making the electrical connection.
D Have the appliance connected by a professional‐ electrician to the equipotential bonding sys­
tem. Its efficiency must be checked in accordance with VDE 0190.
D Set the switch of the appliance to OFF, only then should you plug the mains plug into a cor­
rectly installed plug socket with earth conductor!