9 Troubleshooting

9.1 Identifying and repairing faults

Fault
Unit does not operate at all
CLEANSING, BIDET, DRY, AUTO do not
operate
Remote control does not operate at all
Malfunction of the remote control
No water spray
Low water pressure
1557407-E
Possible cause(s)
Power is off
Power plug is not connected
There is a power failure
Seat is covered
Batteries in the remote control have been
exhausted
The toilet lighting is the three wave lamp
Batteries are empty or too weak
Remote control out of reach of the device
The shut off valve is closed
There is water supply outage
The water pressure level is set to "LO"
The water strainer is clogged
Nozzle head is dirty
Remedy
Press any button to check except "HI", "LO",
"FR", "BK" buttons of the remote control.
Make sure that there is nothing on the seat
surface. (The device is only activated when the
user's skin touches the seat sensor.)
Replace batteries with new ones,
® 4.1 Installation / Assembly, page 10.
Adjust the position of the remote control
or recommend changing the toilet lighting to
normal lamp in case the remote control does
not run in spite of position adjustment.
Replace batteries with new ones,
® 4.1 Installation / Assembly, page 10.
Open shut off valve.
Restore water supply.
Increase water pressure level,
® 5.3 Using the shower toilet, page 17.
Clean water strainer, ® 7.2 Cleaning and care,
page 22.
Clean nozzle, ®7.2 Cleaning and care, page 22.
Troubleshooting