Storing Machine; Troubleshooting - Nobles SPEED SCRUB 15 Manuel Opérateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

STORING MACHINE

Before storing machine, empty tanks and fully charge the
battery.
Store the machine in an open, well--ventilated, dry and
clean area less than 113F/45C in the upright position.
Raise the scrub head to the transport position.

TROUBLESHOOTING

PROBLEM
Machine does not operate.
No vacuum
Poor solution pickup
Brush does not spin
Little or no solution spray.
Little or no solution spray.
Poor scrubbing performance.
Lithium--ion charger is blinking
three green LEDs
AGM charger is blinking yellow
Short battery run time
Nobles Speed Scrub 15 Battery (03- -11)
CAUSE
Discharged battery.
Charger plug is connected.
Defective battery.
Loose battery cable connection.
Vacuum switch not activated.
Tripped vacuum circuit breaker.
Machine is in transport position.
Recovery tank is full.
Clogged squeegee blades or inlet
openings.
Worn or damaged squeegee blades.
Clogged shut--off float.
Clogged vacuum intake screen.
Worn tank cover gasket.
Clogged vacuum hose.
Faulty vacuum motor.
Tripped brush circuit breaker.
Broken brush belt.
Faulty brush motor
Solution tank is empty.
Clogged solution tank screen
Clogged or defective spray tip.
Faulty solution system.
Worn brush.
Output plug not connected to
machine.
Battery not fully charged.
Charger AC cord not plugged into wall
outlet.
Defective battery or charger.
Defective charger plug.
Home
Find... Go To..
If storing machine in freezing temperatures, make
sure to purge all water from solution system.
To purge water from solution system, empty solution
tank, and operate the machine as normal for
approximately 15 seconds.
WARNING: Electrical Shock Hazard. Do Not
Use Outdoors. Do Not Expose To Rain/Moisture.
Store Indoors.
SOLUTION
Charge battery.
Disconnect charger plug.
Replace battery.
Tighten connections.
Turn on vacuum switch.
Turn off main power switch. Remove
obstruction and reset circuit breaker.
Lower scrub head to floor.
Empty recovery tank.
Clean debris from squeegee blades
and both inlet openings.
Replace squeegee blades.
Clean debris from shut--off float.
Clean debris from intake screen.
Contact Customer Service.
Flush out debris buildup from vacuum
hose. See MACHINE
MAINTENANCE.
Contact Customer Service.
Turn off main power switch. Remove
obstruction from brush and reset
circuit breaker.
Contact Customer Service.
Contact Customer Service.
Refill solution tank.
Clean solution tank screen.
Contact Customer Service.
Contact Customer Service.
Replace brush.
Connect output plug securely.
Charge battery.
Plug AC cord into wall outlet.
Replace battery or charger.
Contact Customer Service.
ENGLISH
15

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

90086379008640

Table des Matières