Dimensions of actuator elements
Glass for measuring instrument AM 45
Glass for measuring instrument AM 72
Time
50 Sec
40 Sec
30 Sec
20 Sec
10 Sec
1 Sec
1,5xFLC 10xFLC
20xFLC
30xFLC
Fig. 1
1
2
Interchangeable scale
X = fixing dimensions
14
Explosion-protected control units GHG 43.
1.4
AM45 / AM72 measuring instrument GHG410 98..
EC-Type Examination Certificate:
Marking acc. to 2014/34/EU
and standard of series EN 60079:
(1)
Moving iron
(1)
Moving coil
IECEx type examination certificate:
Category of application
standard of series IEC 60079:
(1)
Moving iron
(1)
Moving coil
Operating temperature:
Rated voltage:
Measuring accuracy:
Overload range:
Measuring range:
40xFLC 50xFLC
Overload
Power consumption:
Coil:
Internal resistance:
Li:
Ci:
Ui:
I i :
Supply terminals:
Test torques:
Weight:
(1)
R....
BVS 14 ATEX E 125U
01 = VM 45
II 2 G Ex eb mb IIC Gb
08 = VM 72
02 = AM 45
II 2 G Ex eb IIC Gb / Ex eb mb IIC Gb
09 = AM 72
20 = AM 45
II 2 G Ex ib IIC Gb
21 = AM 72
IECEx BVS 14.0082U
01 = VM 45
Ex eb mb IIC Gb
08 = VM 72
02 = AM 45
Ex eb IIC Gb / Ex eb mb IIC Gb
09 = AM 72
20 = AM 45
Ex ib IIC Gb
21 = AM 72
-55 °C
... +80 °C
to max. 500 V
Moving iron
class 2.5
10 -
fold
25 -
fold
50 -
fold
telltale 1:1.5
AM:
n / 1A
0 - 25 A direct
VM45:
6 - 415 V
VM72:
6 - 660 V
VM45:
0.91 - 1.76 VA
VM72:
0.91 - 2.65 VA
2 x 0.5 - 2.5 mm²
1 x 4.0 mm²
2.5 Nm
AM/VM 45:
approx. 0.35 Kg
AM/VM 72:
approx. 0.40 Kg
GB
Moving coil
class 1.5
- 25 sec. 10 -
-5 sec.
fold
- 4 sec.
- 1 sec.
0 - 24 mA
4 - 24 mA
26.5 turns
2.5 Ohm +- 30%
max. 0.1 mH
max. 0.1 nF
max. 30 V
max. 150 mA
fine- / multi wire
solid wire