DOSES TRANSFER:
With this function you can program the group on
the left and transfer the doses to other groups.
Fri/09/09 14:45
DOSES TRANSFER
SELECT GROUPS
1.21 bar
Select the group of "target" by pressing the
appropriate button
for the copy of the pro-
gramming and confirm.
NOTE: Group 1 used as a source, is uninhibit-
ed.
DEFAULT SETTING:
This function serves to recall the "Standard
dose" settings for groups.
The display shows:
Fri/09/09 14:45
DEFAULT SETTING
SELECT
1.21 bar
Select the coffee unit to apply the "standard
dose" settings and press the specific button
.
5.2.3
Setpoint
With the ▲ ▼ keys select "SETPOINT" and
press ENTER to access:
Fri/09/09 14:45
LANGUAGE
PROGRAM DOSES
►
SETPOINT
DISPLAY SETTINGS
ENERGY SAVING
COUNTERS
1.21 bar
3 options will be displayed:
Fri/09/09 14:45
►
SETPOINT TEMP.*
SETPOINT PRESSURE
CUP-WARMER PROG.
1.21 bar
SETPOINT TEMP.*:
The display shows the temperature values of
groups and boilers.
Fri/09/09 14:45
SETP. G1
92.8°C
TEMP. G1
1.21 bar
Select coffee / boiler regular group with ▲ ▼
keys and confirm by pressing ENTER.
Using the ▲ ▼ buttons to set the desired tem-
perature for the group / boiler and press ENTER
to confirm the value.
SETPOINT PRESSURE:
The display will show:
SETPOINT PRESSURE
1.21 bar
Using the ▲ ▼ buttons to set the desired pres-
sure for the boiler (see table below). Press
ENTER to confirm the value.
PRESSURE - TEMPERATURE TABLE
Bar
0,50
0,55
0,60
0,65
0,70
0,75
0,80
0,85
Low
0,90
0,95
1,00
1,05
1,10
1,15
1,20
Fri/09/09 14:45
1.20 bar
°C
°F
110,5
230,9
111,5
232,7
112,5
234,5
113,5
236,3
114
237,2
115
239
115,5
239,9
116,5
241,7
117,5
243,5
118
244,4
119
246,2
119,5
247,1
120,5
248,9
121
249,8
122
251,6
53