Series SD 39
• Record the readings of pressure gauge, vacuum meter, am-
peremeter, and if available flow rate gauge and compare
them with further readings under the same conditions (same
valve positioning, outlet-head, inlet water level etc.) and in-
vestigate the reasons for any discrepancies.
• Pressure gauge with three way cock: Only open the three-
way cock in order to obtain a gauge reading and close it im-
mediately afterwards.
• If pumping highly corrosive and/or abrasive media, the
components containing pressure should be inspected regu-
larly to avoid unexpected failure. The interval between in-
spections should be short initially and may be extended as
experience is gained.
5.3
Disassembly and assembly instructions
Stripping and assembly should only be carried out by qual-
ified personnel and with reference to the relevant sectional
drawings (see para. 7.4). The stripping sequence will be
clear from the drawing.
• When disassembling the impeller: The pump
casing remains connected to the pipework.
• When disassembling the pump casing: secure
the pump casing and pipework against falling
down.
5.3.1
Partial flow filters for rinsing the shaft seal in case
of liquids with non-stick admixtures.
The patial flow filter requires no maintenance. When replacing
the floating ring type shaft seal, check and clean also the partial
flow filter system. For this purpose loosen the connecting screw
union at A and B, counterrinse in the direction of the arrow at
the connection A, and wash through from connection B from the
filter at the pipe.
partial flow
filter
washing through
B
A
Partial flow filter
25