Available accessories
Warning
Only use accessories and additional
equipment specified in the instructions.
Using insertion tools or accessories other
than those specified in the instructions
may cause a risk of injury.
Designation
Jigsaw blade set for wood,
10-piece
Jigsaw blade set for metal,
10-piece
Errors and faults
The device has been checked for proper functioning
several times during production. If malfunctions
occur nonetheless, check the device according to
the following list.
Troubleshooting tasks which require the housing to
be opened must only be carried out by an
authorized specialist electrical company or by
Trotec.
Light smoke or odour is emitted during the first
use:
•
This is not a fault. These phenomena
disappear after a brief runtime.
The device does not start:
•
Check the power connection.
•
Check the power cable and mains plug for
damage. If you notice damages, do not try to
take the device back into operation.
If the supply cord is damaged, it must be
replaced by the manufacturer, its service
agent or similarly qualified persons in order
to avoid a hazard.
•
Check the on-site fusing.
EN
Article number
6.215.001.101
6.215.001.131
850W pendulum action jigsaw PJSS 10-230V
Info
Wait for at least 10 minutes before
switching the device back on.
The saw blade is loose:
•
Make sure that the saw blade is firmly locked
in place in the designated recesses of the
quick-release chuck.
•
Make sure that the quick-release chuck is
locked.
The saw blade experiences difficulties
penetrating the material to be processed or the
sawing performance is insufficient:
•
Check the set stroke rate; it must be suitable
for both the saw blade and the material.
•
To select a higher stroke rate, turn up the
setting wheel for stroke rate selection.
•
Check whether the pendulum action setting is
suitable for the material to be processed.
•
If the saw blade is worn, replace it with a
new one.
•
Check whether the chosen saw blade is
suitable for the material to be processed.
The device becomes hot:
•
Make sure not to exert too much pressure on
the device during sawing.
•
To select a low stroke rate, turn down the
setting wheel for stroke rate selection.
•
Check whether the chosen saw blade is
suitable for the task to be carried out.
•
Keep the venting slots clear to prevent the
motor from overheating.
Info
Wait for at least 10 minutes before
switching the device back on.
The device still does not operate correctly after
these checks:
Please contact the customer service. If necessary,
bring the device to an authorised specialist
electrical company or to Trotec for repair.
41