Use other than that intended
Pos: 47 /Alle Produkte/Nicht bestimmungsgemäße Verwendung - Gerät @ 7\mod_1204017770961_121.doc @ 44566
Danger to persons can emanate from this unit if it is not used in accordance with the intended use and in the case of
misuse. If used for purposes other than that intended, our warranty and operating permit will become null and void.
Pos: 48 /Alle Produkte/CE-Herstellererklärung Pumpen @ 6\mod_1194858915864_121.doc @ 40237
CE Manufacturer's Declaration
We declare conformity in the sense of the EC directive, EMC directive (2004/108/EC) as well as the low voltage direc-
tive (2006/95/EC). The following harmonised standards apply:
Pos: 49 /Pumpen/Schlammsauger/Alle Pumpen/Schlammsauger/EN-Normen Pumpen/Schlammsauger @ 0\mod_1126880686869_0.doc @ 5718
EN 60335-1, EN 60335-2-41, EN 55014-2, EN 61000-3-2, EN 61000-3-3
Pos: 50 /Alle Produkte/Unterschrift Wagner @ 3\mod_1147355985402_121.doc @ 18033
Pos: 51 /Alle Produkte/Überschriften/H1 Sicherheitshinweise @ 6\mod_1196353926316_121.doc @ 40981
Safety information
Pos: 52 /Alle Produkte/Sicherheit/SIC Sicherheitshinweise Einleitung @ 7\mod_1205310799730_121.doc @ 45453
The companyOASE has built this unit according to the state of the art and the valid safety regulations. Despite the
above, hazards for persons and assets can emanate from this unit if it is used in an improper manner or not in accor-
dance with its intended use, or if the safety instructions are ignored.
Pos: 53 /Pumpen/Schlammsauger/Air Flow LM/SIC Gefahren durch die Kombination von Wasser und Elektrizität @ 7\mod_1203078822619_121.doc @ 44225
Hazards encountered by the combination of water and electricity
− The combination of water and electricity can lead to death or severe injury from electrocution, if the unit is incorrectly
connected or misused.
− Prior to reaching into the water, always disconnect the power supply to all units used in the water.
Pos: 54 /Pumpen/Schlammsauger/Air Flow LM/SIC Sicherer Betrieb des Gerätes @ 7\mod_1203079033604_121.doc @ 44251
Safe operation of the unit
− Only switch on the unit with the riser pipe fitted.
− Only operate the unit if no persons are in the water.
− Keep the power plug dry.
− Route the power cable so that damage is excluded.
− Do not carry or pull the unit by the power cable. The power connection cable cannot be replaced.
− Never run the unit without water. The unit will be destroyed.
− Never use the pump for fluids other than water. Other fluids could destroy the unit.
− Never open the unit housing or its attendant components, unless this is explicitly mentioned in the operating instruc-
tions.
− Never carry out technical modifications to the unit.
Only use original spare parts and original accessories for the unit.
Pos: 55 /Pumpen/Schlammsauger/Air Flow LM/SIC Vorschriftsmäßige elektrische Installationen @ 7\mod_1203079099432_121.doc @ 44277
Correct electrical installation
− Electrical installations at ponds must meet the international and national regulations valid for installers.
− Electrical installations may only be carried out by qualified electricians.
− Only use cables approved for outside use.
− Ensure that the unit is protected by for a rated fault current of max. 30 mA via a fault current protection device.
− Only operate the unit when plugged into a correctly fitted socket. Keep the socket dry.
− Only connect the unit when the electrical data of the power supply is identical to that on the unit type plate.
Pos: 56 /Alle Produkte/Überschriften/H1_Montage @ 7\mod_1202907725390_121.doc @ 43908
Installation
Pos: 57 /Pumpen/Schlammsauger/Air Flow LM/Montage Air Flo @ 7\mod_1202907923515_121.doc @ 43960
Nozzle assembly (B)
Attention! Danger emanating from the propeller rotating at high speed.
Possible consequences: Severe injury to limbs.
Protective measures: Pull the power plug prior to starting any work on the propeller unit (1) and secure it
from unintentional plugging in again. The motor will start running as soon as the power plug is plugged in
the power socket.
Riser pipe installation: Place the riser pipe (2) on the propeller unit (1) and tighten using the four screws (10) and
washers (11).
Nozzle installation for water image effect I or II: Place the protection grid (7), O ring (6) and the respective nozzle (4 or
5) on the riser pipe (2). Tighten using screws (10), washers (11) and nuts (12).
Nozzle installation for water image effect III: Place disc (8) on the propeller such that the grub screws at the propeller
and the bore holes in the disc (8) are congruent one on top of the other. Fasten disc (8) with screw (9). Place the
protection grid (7), O ring (6) and the nozzle (4) on the riser pipe (2). Tighten using screws (10), washers (11) and nuts
(12).
Note: Adhere to the nozzle-disc combination according to the table. Other combinations are not permissible.
- GB -
Signature:
13