CONVERSION OF ELECTRICITY SUPPLY
The appliance is supplied at an operating voltage
400V/3N (indicated on the sticker applied to the da-
taplate); conversion to 230V/3 can be carried out as
described below.
Caution - warning
Before doing any work, cut off the mains elec-
tricity supply.
1 - Remove the control panel (A).
2 - Fit the jumper (B) to make the electrical connec-
tion of the terminals (C) and (D).
3 - Change the connections of the terminal
board (E) as shown in the diagram.
4 - Replace the control panel (A).
5 - Remove the test voltage indicator sticker from
the dataplate and apply the new one to identify
the voltage being used.
Important
On completion of the operation make sure
that there are no malfunctions.
RESETTING THE APPLIANCE
If the safety thermostat is tripped, the appliance has
to be restored to working conditions as follows.
1 - Allow the oil to cool to 30-40°C.
2 - Press the button (A) of the safety thermostat to
restore the electricity supply.