APPENDIX A / ANNEXE A
COMMAND RESPONSE
COMMANDE RÉPONSE
CONTROLS COMMANDS / COMMANDES DU MENU CONTROL
xU
VERU
xI
I_
yo
OPT
QE
EPD
yl
LOCK
yi
EISP
ye
EPOS
Y
FRES
fr
BFCR
fb
BFCB
fg
BFCG
COMMUNICATION PORT COMMANDS / COMMANDES DE COMMUNICATION
ne
LANE
nr
LANR
ns
LANS
na
ADIP
nw
IPA_
nx
IPB_
ny
IPC_
nz
IPD_
np
PORT
nk
NTMK
nt
TCP
GENLOCK COMMANDS (ULTRA VIO only) / COMMANDES DU GENLOCK (ULTRA VIO uniquement)
GR
GENR
GA
GENA
GF
GENF
GT
GENT
GS
GENS
GP
GENP
GL
GENL
OTHERS COMMANDS / AUTRES COMMANDES
yS
STO
?
DEV
#
DEV......
NOTE:
Rd = Read only command / Commande de lecture.
PAGE 64
COMMAND DESCRIPTION
DESCRIPTION DE LA COMMANDE
Device version.
Identification number.
Options available.
2:2 pull down correction.
Key locking.
Auto-lock
Erase memories.
DEFAULT VALUE.
Red level adjustment of the FADE.
Blue level adjustment of the FADE.
Green level adjustment of the FADE.
Communication port selection
Reset of the LAN parameters.
Store the LAN parameters.
IP address and port selection (for
modification)
First byte of the address selected by the
na command.
Second byte of the address selected by
the na command.
Third byte of the address selected by the
na command.
Forth byte of the address selected by the
na command.
Number of the port (local or remote)
selected by the na command.
Netmask.
Protocol selection.
Genlock reference selection
Genlock reference status
Genlock type
Frame frequency of the genlock signal Rd
Sub carrier adjustment of the genlock.
Horizontal adjustment on the genlock
Genlock input load
Image parameters storing.
Device type.
Send all device parameters.
TYPE
MIN MAX
Rd
0
65535 Example: 104 = Version 1.4
Rd
0
65535 Value displayed in hexadecimal in the device.
0
65535 0 = without option.
Rd
Rd/Wr
0
1
0 = off
Rd/Wr
0
1
0 = unlocks
Rd/Wr
0
1
0 = off
Rd/Wr
0
1
1 = erase all memories (automatic reset).
Rd/Wr
0
1
1 = Default value action (automatic reset).
Rd/Wr
0
255
Rd/Wr
0
255
Rd/Wr
0
255
Rd/Wr
0
1
0 = RS232
Rd/Wr
0
1
1 = reset.
Rd/Wr
0
1
1 = store.
0 = all IP address / ports
1 = IP local address / local port
Rd/Wr
0
3
2 = IP remote address / remote port
3 = IP gateway address.
Rd/Wr
0
255
Rd/Wr
0
255
Rd/Wr
0
255
Rd/Wr
0
255
local port: 10000 to 10999.
Rd/Wr
0
65500
remote port: 0 to 65500.
Value = number of bit to 0 (from right).
example: 2
Rd/Wr
0
24
Rd/Wr
0
1
0 = UDP
0 = internal
Rd/Wr
0
3
2 = HDTV
0 = internal
Rd
0
3
2 = HDTV
0 = no signal.
2 = NTSC (3.58/60).
4 = 1080i @ 50 Hz.
Rd
0
10
6 = 1080i @ 60 Hz.
8 = 720p @ 59.94 Hz.
10 = 480p @ 60 Hz.
0
65535 Value in hundredth of Hz
Rd/Wr
0
255
Rd/Wr
0
127
Rd/Wr
0
1
0 = Hi-Z
Rd/Wr
0
1
1 = STORE action (automatic reset).
Rd
0
65535 30 = VIO1600
Rd
Rd/Wr = Read and write command / Commande de lecture et d'écriture.
VIO1600 & ULTRA VIO
VALUE /VALEUR
DESCRIPTION
1 = auto.
1 = locks
1 = on.
1 = LAN
255.255.255.252
3
255.255.255.248
.............
8
255.255.255.0.............
24
255.0.0.0
1 = TCP
1 = SDTV
3 = error
1 = SDTV
3 = error
1 = not compatible.
3 = PAL (4.43/50).
5 = 1080i @ 59.94 Hz.
7 = 720p @ 50 Hz.
9 = 720p @ 60 Hz.
1 = 75 ohms
35 = ULTRA VIO