[6]. To exit programming mode:
- place the master tag in front of the tag reader, or
- wait 10 seconds a er the most recent progamming operation.
The external module emits two low-pitched "beeping" sounds in
order to indicate that it is in operational mode.
Place a tag in front of the tag reader:
If the tag is programmed, the external module emits two high-
pitched "beeping" sounds and its relay is activated.
If the tag is not programmed, the external module emits three
low-pitched "beeping" sounds and its relay is not activated.
The following procedure will clear the programming on all user tags.
Clearing the user tag programming is carried out on the external module using the master
tag to run the procedure:
[1]. Place the master tag in front of the tag reader.
Le module extérieur émet deux «bip» aigus.
[2]. Press the call button (the lower call button in the case of an external 2-button
module)
The external module emits a low-pitched continuous "beeping"
sound.
[3]. Release the call button.
The low-pitched "beeping" sound stops.
[4]. Press and hold down the call button and place the master tag in front of the tag
reader.
The external module emitts two low-pitched "beeping" sounds,
all user tags have been cleared and the external module exits
programming mode.
4

4 USING TAGS

5 CLEARING USER TAGS

Copyright © 2016 Somfy SAS. All rights reserved.
BIP
BIP
BIP BIP
BIP BIP BIP
BIP BIP
BIIIIIP
BIP
BIP