Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Network Setup

Make the various settings to use the network function.
SET UP
MULTI DISPLAY SETUP
MULTI PIP SETUP
PORTRAIT SETUP
SET UP TIMER
PRESENT TIME SETUP
NETWORK SETUP
DISPLAY ORIENTATION
NETWORK SETUP
SAVE
DHCP
IP ADDRESS
SUBNET MASK
GATEWAY
PORT
LAN SPEED
NETWORK ID
CONTROL I/F SELECT
MAC ADDRESS
SAVE
Save the current network Setup. Each value set for
DHCP, IP address, Subnet mask, and Gateway will
be saved. If "NG" is displayed, check the same IP
address is not used within the same network.
DHCP (DHCP client function)
To obtain an IP address automatically using a
DHCP server, set this to "ON". If DHCP server is
not used, set this to "OFF".
IP ADDRESS (IP address display and setting)
Enter an IP address if DHCP server is not used.
SUBNET MASK (Subnet mask display and setting)
Enter a subnet mask if DHCP server is not used.
GATEWAY (Gateway address display and setting)
Enter a gateway address if DHCP server is not used.
PORT
Set the port number used for command control.
The available setting range is 1024 – 65535.
When the PJLink™ protocol is used, the port
setting is not necessary.
Notes:
• To use a DHCP server, make sure the DHCP server is started.
• Contact your network administrator for details on settings.
4
2/2
DHCP, IP ADDRESS, SUBNET MASK, and GATEWAY settings
1
Set DHCP.
When "OFF" is selected, IP ADDRESS and other settings
can be set manually.
2
Select the item and press
3
LANDSCAPE
Enter an address.
IP ADDRESS
I
192.168.
4
Select "SAVE" and press
OFF
192.168. 0. 8
PORT setting
255.255.255. 0
1
192.168. 0. 1
Select "PORT" and press
2
Enter a port number.
1024
AUTO
PORT
0
I
01024
RS-232C
--:--:--:--:--:--
.
1
Use
to select a digit.
0.
8
2
Use
to change a number.
3
Press
.
Pressing
will cancel the address
change.
.
.
1
Use
to select a digit.
2
Use
to change a number.
3
Press
.
Pressing
will cancel the port
number change.
LAN SPEED
Set the connection speed of the LAN environment.
Select the value from AUTO, 10 HALF, 10 FULL,
100 HALF or 100 FULL.
NETWORK ID
Set the ID to identify this unit.
The available setting range is 0 – 99.
CONTROL I/F SELECT
Set whether to control with RS-232C (serial) or
LAN. When "LAN" is set, power indicator is lit
orange when the slot power is turned on, then the
power is turned "OFF" with remote control (stand-
by state) regardless of the "Slot power" setting.
MAC ADDRESS
Display the MAC address of this unit. However,
the MAC address is not displayed when the
"CONTROL I/F SELECT" is set to "RS-232C".