Technical data
Voltage:
Max. current consumption:
Power cord:
Acceptance capacity:
Max. operating pressure:
Volume flow at 12 MPa
(120 bar) with water:
Max tip size:
Max. temperature of the
coating material:
Max viscosity:
Weight:
Special high-pressure hose:
Dimensions (L X W X H):
Max sound pressure level:
* Place of measuring: 1 m in distance from the unit and 1.6
m above the floor, 12 MPa (120 bar) operating pressure,
reverberant floor.
3.6
Transportation in vehicle
Secure the unit with a suitable fastening.
220-240 Volt , 50/60 Hz
6.0 A
3 x 1.5 mm
– 6 m
2
1035 Watt
221 bar (22.1 MPa)
2.3 l/min
0.024 inch – 0.61 mm
43°C
20.000 mPa·s
17.7 kg
DN 6 mm, 15 m, connection
thread M 16 x 1.5
436 x 369 x 416 mm
80 dB (A) *
GB
4.
Starting operation
4.1
High-pressure hose, spray gun and separating
oil
1. Screw the pressure gauge (1) to the coating material outlet
(Fig. 2, Item 2).
2. Screw the high-pressure hose (3) to the coating material
outlet on the pressure gauge (Fig. 2, Item 4).
3. Screw the spray gun (5) with the selected tip onto the high-
pressure hose.
4. Tighten the union nuts at the high-pressure hoses firmly so
that coating material does not leak.
1
4
2
3
5. Remove the oil cup cap with a straight-slot screwdriver.
6. Fill the oil cup with EasyGlide (Fig. 3) until the oil gauge (6) is
showing that it is full.
EasyGlide prevents increased wear and tear to the
packings.
Attention
7. Replace oil cup cap.
8. Press oil button 2-5 times to prime the oiler. Press once for
every eight hours of usage to lubricate the fluid section.
9. Fully depress the pusher stem to make sure the inlet ball is
free.
26
Starting operation
5
ProSpray 3.23